Use and Care Manual
Table Of Contents
PREPARING THE SPACE
Make sure that the opening where the unit is to
be installed is properly prepared. Refer to
Figure 1 to ensure the space dimensions and
electrical service are correct for the models to be
installed.
CAUTION
If unit is being installed under a counter top
it is recommended that the counter top be
supported by structure other than the
refrigerated cabinet to prevent damage to the
counter top.
IMPORTANT NOTE: Allow 24” clearance in
front of the unit for drawer pull-out.
IMPORTANT NOTE: Make sure the floor under
the unit is level with the surrounding finished
floor. Protect a finished floor with plywood,
cardboard or some other suitable material
before moving the unit into place. Failure to do
this may result in damage to the floor.
PREPARING ELECTRICAL
CONNECTIONS
A 115 volt, 60Hz, 15 amp circuit with GFI
protection and electrical supply are required. A
separate circuit is required for each Lynx unit
installed.
Follow the National Electrical Code and local
codes and ordinances when installing the
receptacle.
All Lynx units come equipped with a NEMA 5-
15P 90° plug with a minimum of 5-feet of cord
extending beyond the rear of the cabinet. The
electrical outlet must be flush with or recessed
into the back wall.
IMPORTANT NOTE: Never use an extension
cord to extend the power cord to the electrical
receptacle.
DANGER
ELECTROCUTION HAZARD!!
Electrical grounding required. This appliance is
equipped with a three prong (grounding)
polarized plug for your protection against
possible shock hazards.
Never remove the round grounding prong
from the plug.
Never use a two-prong grounding adapter.
Never use extension cord to connect power
to the unit.
Where a two-prong wall receptacle is
encountered or a longer power cord is required,
contact a qualified electrician to have it replaced
in accordance with applicable electrical codes.
DANGER
Failure to comply with the above electrical
guidelines may result in possible injury/death/fire
or loss of property.
UNPACKING AND MOVING
CAUTION
Do not cut cardboard sleeve covering the unit.
Cutting may result in damage to the exterior of
the cabinet.
1. Uncrate the unit outside on a flat level
surface. Remove the cardboard sleeve
by removing the banding holding the
sleeve to the shipping base. Carefully lift
the cardboard sleeve up over the top of
the unit.
2. Carefully lift unit off base and onto a
hand truck or dolly (this should be done
with a minimum of two people; larger
units may require additional helpers).
Make sure unit is balanced on
transporting device. Secure unit to
transporting device using soft, flexible
strapping. Protect unit surfaces with
cloth material where strapping contacts
unit.
3. Before moving unit, secure door to unit
with tape to the door closed.
4. Carefully move unit to installation site
and place in front of opening.
WARNING
A minimum of two people should lift the unit of
the base to prevent possible personal injury.