Asado Cooktop Care & Use Manual (L30AG / L30AGF)
12 | Use&Care / Installation
GAS CONNECTIONS con’t
For freestanding units using natural gas, Lynx recommends
using a mobile fl ex gas line. Always keep the line away
from the fi rebox.
This is available at your local hardware store or from your
dealer.
LP GAS
Grills set up for LP gas come equipped with an LP hose/
regulator assembly for connection to a standard 20 lb. LP
cylinder. (Type 1). All fi ttings necessary to attach the assem
bly to the grill are included.
Permanently plumbed LP connections, such as those in
line with a bulk cylinder, require a 4/11 regulator. (Lynx P/N
30781)
When using the 4/11 regulator you must ensure that it is
set for the proper fuel type. This is done by removing the
regulator cap and gasket and looking at the bottom of the
plunger to see what fuel type is visible. This is the regula
tor fuel setting. NAT is for natural gas and LP is for propane
gas. The LP setting can be further identifi ed by the large
diameter disk on the bottom of the plunger. To change
from one gas to the other simply push the plunger to the
side to snap it out of the cap, turn the plunger so it reads
the desired gas type on the bottom, and push the plunger
until it snaps back into place in the cap then replace the
cap into the regulator.
Never connect an unregulated gas line to the grill.
WARNING
Do not change the regulator/hose assembly or use any
other assembly than the one supplied with your Lynx
grill.
Do not attempt to use a SLP-A equipped regulator/
hose assembly with a standard 510 POL cylinder/valve
assembly.
Do not store a spare LP-gas cylinder under or near this
appliance.
Never fi ll the cylinder beyond 80 percent full.
If the information above is not followed exactly, a fi re
causing death or serious injury may occur.
LP CYLINDER REQUIREMENTS
The LP cylinder must be constructed and marked in accor
dance with the specifi cations for LP gas cylinders of the U.S.
Department of Transportation (DOT) and designed for use
with a Type 1 system only.
Cylinders of free standing grills must be secured using
the provided cylinder retention system to avoid accidental
movement.
When exchanging your
cylinder for a refi ll, exhange
only for a Type 1 2016
cylinder with an over-fi ll
protection device.
Never use a cylinder with a damaged valve.
Always check for leaks after every LP cylinder change. (See
: “Leak Test” for further details.).
Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children. If your grill is stored indoors,
the LP cylinder must be stored outside.
LP cylinder with type 1 valve connection