BEFORE YOU START
WARNING
• Never install this product into a combustible enclosure without an insulated jacket. Doing so could result in fi re,
property damage and personal injury.
• Never locate the grill under an uprotected roof or overhang, in a building, garage, shed or other such enclosed
area.
• Never locate the grill under unprotected combustible construction.
• Installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Natural Gas and propane Installation Code, CSA B149.1, or Propane Storage and
Handling Code, B149.2, in Canada.
IF SHIPMENT ARRIVES DAMAGED
VISIBLE LOSS OR DAMAGE
Be certain any visible damage to the carton is noted on
freight bill or express receipt and signed by the person
making delivery. FILE CLAIM FOR DAMAGES IMMEDIATELY,
regardless of extent of damage.
IMPORTANT NOTES
HOW LONG IS YOUR RUN?
Keep all gas supply lines as short as possible because
gas lines lose pressure over distance and with each elbow
and tee that is added. This drop in pressure a ects grill
performance. (See: “Gas Supply Line Runs” for further
details.)
CONCEALED LOSS OR DAMAGE
If damage is unnoticed until the grill is unpacked, notify
the transportation company or carrier immediately and
fi le a “concealed damage” claim with them. This should
be done within (5) days of the date delivery is made to
you. Be sure to hold on to the container for inspection.
We cannot assume responsibility for damage or loss
incurred in transit. (See: “Obtaining Service from Lynx”
for further details.)
ARE YOU “ON THE LEVEL”?
Proper leveling during installation is critical. A grill that
is out of level will cause erratic burner combustion and
ine cient, uneven heating. A carpenter’s spirit level
should be used to level the grill both front-to-back and
side-to-side.
BUILT-IN INSTALLATIONS
The Lynx Built-In Grill is designed for easy installation into
masonry enclosures.
NOTE: Lynx built-in grills are intended either for installation
in a built-in enclosure constructed of
non-combustible materials or for an installation in a built
in enclosure constructed of combustible material when
installed with a Lynx insulating jacket (LIJ).
For non-combustible applications, the grill drops into the
opening shown in the cutout detail drawing (See: “Gas
Requirements”) and hangs from its counter-top trim. A deck
is not required to support it from the bottom.
When using the insulated jacket in a combustible enclosure,
the jacket must be supported from the bottom by a ledge
on each side or a full deck beneath the jacket.
(See: "Gas Requirements") Pay special attention to the
provisions shown for gas line hook-up.
The enclosure should have ventilation holes to prevent
gas build-up in the event of a leak. The deck ledges
and counter should be fl at and level. (refer to ANSI
Z21.58 Standard for Outdoor Cooking Gas Appliances,
Section 1.7 Enclosures For Self Contained LP-Gas Supply
Systems).
This grill requires that a 120 volt, 60 hertz, 15 amp GFI
certifi ed outlet be installed by a qualifi ed electrician.