Sedona Grills Use and Care

26
|
SEDONA CARE & USE/INSTALLATION
Ensure that the gas supplied meets with the minimum
pressure requirements. Do not operate the grill on any gas
other than that for which the grill has been set.
Fuel WC Max Inlet WC Min Under Full
Load
Nat Gas 7 in 4 in
LP 14 in 11 in
Water Column Requirements
Both the regulator and the manifold orifices have been
tuned for the type of gas specified on the rating plate.
All installation and all installation parts must conform
to local codes with the National Electrical Code, ANSI
Z223.1/NFPA 70 latest edition and the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 in the U.S and CGA-
B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
NATURAL GAS
It is recommended that only qualified professionals per-
form the required plumbing on this product.
To ensure satisfactory performance, the gas supply line
must be sized to accommodate the total BTU requirements of
all the gas-fired equipment that will be connected to that line.
In no case should pipe less than ¾” inside diameter or 1”
outside diameter ever be used to connect this product.
Calculate the total BTU output of all equipment and
refer to “INDEX: Gas Supply Line Runs” for allowable run
distances for ¾ inch pipe. Failure to meet these minimum
requirements may reduce performance of the grill and
any other appliances running on that supply line.
Always keep supply line runs as short as possible. (See
INDEX: “BTU Output” for specific model outputs)
A gas shut-off valve must be installed in an easily acces-
sible location by a qualified plumber.
Keep threading compound off of the first two pipe
threads to avoid having any small pieces of compound
break loose and clog a burner valve or orifice. Do not use
threading compound on any flare fittings.
For built-in installations, it is recommended that any flexible
pipe used be kept as short as possible. (See INDEX: “Gas
Connections” for typical permanent hook up.)
BOTTLED LP HOOK-UP
2 Typical LP Bottle
Installations
NATURAL GAS HOOK-UP
3 Typical Natural Gas
Installations
GAS CONNECTIONS... continued
Keep last two
threads clean