In the unlikely event you lose cooling in your unit, do not
unplug the product from the electric supply, but do call
a qualied service technician immediately. It is possible
that the loss of cooling capacity is a result of excessive
frost build-up on the evaporator cooling coil. In this case,
removing power to the unit will result in the melting of this
excessive quantity of ice, which could generate melt water
that exceeds the capacity of the defrost drain system and
could result in water damage to your home. The end-user
will be ultimately responsible for any water damage caused
by prematurely turning the unit off without appropriately
managing the excess water run-off.
• Never attempt to repair or perform maintenance on
the appliance until the main electrical power has been
disconnected. Turning the appliance control "OFF"
does not remove electrical power from the unit's wiring.
• Replace all parts and panels before operating.
!
WARNING
Electrocution Hazard
TROUBLESHOOTING
Before You Call for Service
If the appliance appears to be malfunctioning, read through
this manual rst. If the problem persists, check the trouble-
shooting guide below. Locate the problem in the guide and
refer to the cause and its remedy before calling for service.
The problem may be something very simple that can be
solved without a service call. However, it may be required
to contact your dealer or a qualied service technician.
Problem Possible Cause Remedy
Appliance not cold enough
(See “Adjusting the temperature" on page 11)
Control set too warm
Content temperature not stabilized.
Excessive usage or prolonged door open-
ings.
Airow to front grille blocked.
Door gasket not sealing properly.
Adjust temperature colder. Allow 24 hours
for temperature to stabilize.
Allow temperature to stabilize for at least
24 hours.
Airow must not be obstructed to front
grille. See “clearances” on page 4.
Replace door gasket.
Appliance too cold
(See “Adjusting the Temperature” on page 11)
Control set too cold
Door gasket not sealing properly.
Adjust temperature warmer. Allow 24 hours
for temperature to stabilize.
Replace door gasket.
No interior light. Failed LED light assembly or light switch. Contact a qualied service technician.
Light will not go out when door is closed Door not activating light switch.
Failed light switch
Appliance not level, level appliance, (See
page 4, “leveling legs”)
Contact a qualied service technician.
Noise or Vibration Appliance not level
Fan hitting tube obstruction.
Level appliance, see “Leveling Legs” on
page 4.
Contact a qualied service technician.
Appliance will not run. Appliance turned off
Power cord not plugged in.
No power at outlet.
Turn appliance on. See “Starting your ap-
pliance” on page 10.
Plug in power cord.
Check house circuit.
!
CAUTION
NOTE
Your product has an automatic defrost feature that utilizes
an electric heater element. Periodically during defrost you
may observe the following:
Water dripping and running sounds as a result of the
frost melt.
Sizzling and popping sounds from water dripping on
the heater element.
A faint reddish glow in the freezer compartment from
the electric heater element.
These are all “normal” operating characteristics related to
refrigeration product incorporating automatic defrost. They