If an RDFLT or R= command is executing, do not power down the SSC-32 until the command
has completed. To determine whether the command has completed, read a register value.
Each time a register is written, the EEPROM location(s) used to store the value experience a
small amount of wearout. The typical maximum number of writes is 100,000. Do not write your
software to rapidly change the register values, or you might cause a permanent wearout of the
EEPROM in the ATMega168 processor.
Miscellaneous Register Commands
Command
Argument
Description
Examples
STOP <n>
<cr>
0-31
Immediately stops the specified
servo at its current position. A
space is optional before the
servo number.
STOP0 <cr>
STOP 31 <cr>
If the servo is part of a timed move, the other servos will continue moving and a query command
will indicate that the move continues until the total time for the original move has elapsed. This
is true even if all
of the servos in the original move are stopped.
The EER and EEW commands no longer work to access internal EEPROM. They are replaced
by Register Read/Write and Startup String commands. EER and EEW continue to function for
external EEPROM.