Specifications

STANDARD LOCKER SPECIFICATIONS
(KNOCKED DOWN)
Material - Prime, high grade Class 1 mild annealed, cold-rolled steel free from surface imperfections. A.S.T.M.-A1008. Galvannealed
steel available for high humidity atmospheres. A.S.T.M.-A653. Bolts to be zinc plated or subjected to other rust-retardant treatment.
Body - 24-gauge steel, flanged to give double thickness of metal at back vertical corners.
Door Frame - 16-gauge formed steel channels. Vertical members shall have an additional flange to form continuous door strike.
Corners shall be lapped and welded into a rigid assembly. In addition, bottom cross members shall have tang at each end that fits
through slot in rear flange of upright frame member to prevent twisting out of alignment. Top and bottom cross members shall provide
support for front edge of locker top and locker bottom.
Door - One-piece, 16-gauge steel on single, double and triple tier with both vertical edges formed into channel-shaped formation; top
and bottom shall be flanged at 90 degree angle. On multiple tier lockers, hinge side shall be formed into channel shaped formation with
other three sides flanged at 90 degree angle.
NOTE: Box locker doors up to and including 15" wide by 15" high shall be 18-gauge unless specified otherwise.
Ventilation - Louvers shall be provided as follows:
Locker Styles Louvers
Single/Double tier lockers – 9"w Six 3-1⁄2" louvers top and bottom.
Single tier lockers – Over 9"w Six 6" louvers top and bottom.
Double tier lockers – Over 9"w Six 6" louvers top and bottom.
Triple tier lockers – 9"w Two 3-1⁄2" louvers top and bottom.
Triple tier lockers – Over 9"w Two 6" louvers top and bottom.
Multiple tier lockers Three 3-1⁄2" louvers per door for 12" and 15" wide lockers.
Four 6" louvers per door for lockers 18" wide and over.
Door Jambs - 48" and higher single tier lockers shall have three door jambs; double tier and triple tier lockers shall have two jambs
welded to side of door frames to engage locking device. Design and gauge of jamb shall prevent freeing of locking device by prying.
Each jamb shall have easily replaceable soft rubber bumper.
Hinges - Shall not be less than 2" high, .050" steel, 5 knuckle, and full loop design forming double thickness on each leaf. Hinges to be
set in slot in door and frame and projection welded to frame and securely attached to door; Hinge pin to be spun over at ends to resist
removal. Single-tier lockers 48", 60" and 72" high to have three hinges. All other tiers to have two hinges – all on right hand side of
door.
Quiet Locking Device - Single tier locking device shall engage frame at three points; double tier and triple tier at two points. Channel
shaped locking device with full length reinforcing ribs shall be a quiet design utilizing nylon guide inserts to reduce metal-to-metal
contact. The locking device shall include a latch finger that engages the 12-gauge door jamb. Lock bar shall be enclosed on three sides
and operate within the channel formation of the door. Locking device shall be prelocking so mechanism can be locked in open position
– door locking automatically when closed. An optional single point latch shall be available except on 9" wide lockers. Box lockers shall
have one-point locking device with a 14-gauge lock clip for attaching padlock. Doors also to be provided with lock hole filler to permit
use of built in lock.
Handles - On single, double and triple tier lockers, handles shall be recessed. No moving parts are to operate against outside surface
of locker. Padlock attachment to be integral part of lift, which shall be attached directly to locking bar and protected by fixed handle
housing. Handle to provide built in padlock strike. The recessed handle shall be 4-1⁄8"w x 6-1⁄16"h x 1-1⁄4"d. Multiple tier lockers shall
be equipped with a 16-gauge door pull with padlock attachment when not used with built in locks.
Shelves - Single tier lockers shall have one 24-gauge shelf approximately 9" below top. Flanged on all four sides for strength with the
front flange turned 45 degrees for safety and attached at no less than two points through each side flange. Only single tier lockers have
shelves.
Coat Hooks - Single tier, double tier and triple tier lockers shall have one double prong hook and three single prong wall hooks. 5⁄8"
diameter coat rods are standard in 18" and 21" deep knocked down single tier lockers, replacing ceiling hook. All hooks to be zinc
plated or subjected to a comparable rust retardant treatment and attached with two bolts.
lyonworkspace.com | PO Box 671, Aurora, IL 60507-0671 | phone 630-892-8941 | fax 630-892-8658 Page 1