5. FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
Dry chemical, CO2, water spray or regular foam. Dike fire-control water for later disposal.
Unsuitable extinguishing media
Do not use halogenated extinguishing agents or foam. Do not scatter spilled material with high pressure water streams.
Specific hazards arising from the chemical
Some may burn but none ignite readily. Some may be transported hot.
Uniform Fire Code
Sensitizer: Liquid
Combustible Liquid: III-B
Irritant: Liquid
Hazardous Combustion Products
Carbon oxides.
Explosion Data
Sensitivity to Mechanical Impact
No.
Sensitivity to Static Discharge
No.
Protective equipment and precautions for firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal precautions
Do not touch or walk through spilled material. Stop leak if you can do it without risk.
Other Information
Refer to protective measures listed in Sections 7 and 8.
Environmental precautions
Environmental precautions
Prevent entry into waterways, sewers, basements or confined areas.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Take up with sand, earth or other non-combustible absorbent material. With clean shovel
place material into clean, dry container and cover loosely; move containers from spill area.
Soak up with inert absorbent material. Pick up and transfer to properly labeled containers.
_____________________________________________________________________________________________