LUNA GOLD+ COLLECTION INSTRUCTION FOR INSTALLATION AND USE Passion for fire English - 08/2011 INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
V E RY I M P O R TA N T I N S T A L L A T I O N INSTRUCTIONS FOR THE M - D E S I G N GAS FIREPLACES T H E S U P P L I E R TA K E S N O RESPONSBILITY FOR ANY POSSIBLE DAMAGE, POOR WORKING APPLIANCES AND ACCIDENT AS A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
SUMMARY 1. GENERAL..................................................................................... 4 1.1 TRANSPORT AND INSTALLATION................................ 4 1.2 TYPES OF FUEL...................................................................... 1.2.1 Wood 1.2.2 Forbidden fuel 4 1.3 STARTING THE FIRE........................................................... 5 2. INSTALLATION......................................................................... 6 2.
1. GENERAL 1.1 TRANSPORT AND INSTALLATION • Transport the Luna in an upright position, or, in encumbering circumstances, at an angle of 45°. • The handles for transportation purposes have been attached inside the slots provided on the sides of the Luna (see Pic.1) • A set of rubber straps that can be turned and a set of fixed rubber straps are available as an option. This is to facilitate transport on-site and on the stairs.
1.3 STARTING THE FIRE • Open the window (pic.3). • Put a bed of tinder (paper or firelighters) with a little kindling (small twigs or pieces of wood) in the stove and light the tinder. • Leave the door slightly ajar (+ 3 cm) to get a turbo stream of air that will make the kindling catch fire. •After the kindling has caught fire and burns well, the logs may be placed on the fire. After the logs have caught fire, the window may be shut.
2. INSTALLATION 2.1 ACTIONS TO BE TAKEN UPON INSTALLATION Your supplier is the specialist who chose to represent M-design in your area. For your own safety and satisfaction, we advise you to entrust him with the installation. The appliance has to be installed according to certain prescribed rules and local regulations. In the absence of the correct regulations in Belgium, the French regulations in respect of installation will be (D.T.U. 24.2.2) applicable.
2.3 INSULATION AND FINISHING Please , follow this instruction. The appliance can overheat if you not apply those instructions. Once installation is complete, the appliance can be fitted. Once you have checked everything, you can perform the final insulating and finishing operations. The built-in part of the furnace tends to be very warm. Please check that the furnace is not too narrowly fitted and that there is adequate space for the elimination of hot air.
2.4 MOUNTING A 3-SIDED FRAME ( see page 23 and 24 drawings 3-sided frame and 4th side ) First remove the profile that is delivered with the fireplace ( pic. 1 ) The 3 sided frame consist of 3 parts and are assembled to the Luna ( pic. 2 ) Fixing to frame with the included screws ( pic.3 ) the 3 sides frame and his 3 parts pic.2 pic.1 pic.
2.5 AIR SUPPLY FOR COMBUSTION Every form of combustion uses air. In the case of a thermally sealed room supplementary air supply is essential. One must at all times avoid creating under-pressure in the room. If a cooking hood appears to be absolutely essential in the adjoining room, sufficient air supply will have to be provided to avoid every form of under-pressure. You need an airlet with dia. 150mm coming from outisde, or a ventilated shelter. This airinlet you have to connect to the Luna.
2.6 CONVECTION CURRENT 2.6.1 Natural convection It is compulsory to open 2 or 4 hot air vents (see table 1) at the top of the appliance. The entrance for the air supply convection are situated at the lower backside of the Luna Gold+ and also through the opening that is provided for the fan. These have been constructed in such a way that no air can be blown out along here, not even with a fan. The stove is placed at least 20 mm above the floor (if placed on the floor) to allow for natural convection.
INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD 2 dm² Inlet Grid convection air Design Grid ( outlet ) with 2 connections EACH APPERTURE YOU MAKE, MUST BE CONNECTED WITH FLEXIBLE OR Design Grid ( outlet ) with 2 connections 4 dm² Inlet Grid convection air OR Design Grid ( outlet ) with 4 connections
The grids are provided with two connections. 2 flexibles for one grid ! Two holes between the two connection provides ventillation in the maconry. To simplify the mounting of the grids you can use the corner profile wich is furnished with the grid. This profile is can be mounted on the side of the grid (two little wholes en screws are provided). corner profile Note: a circulation of hot air requires that no under-pressure be created in the room.
2.8 FLUE 2.8.1 Flue The construction of chimney must comply with strict conditions: All the Luna stoves have a standard flue opening of 250 mm. in diameter. Certain chimney configurations may require different standard diameters. In that case, look at table for the height of the flue and the possibility of reducing the diameter with the help of a reduction piece. Note : per 45° change of direction, one must keep to within 1m of this table. • The flue must be thermally insulated.
2.9. HOW TO REGULATE FIREPLACE IN SENSE OF DROUGHT 2.9.1 Baffle plate The stoves have all been provided with an automatically adjustable baffle plate. This can be adjusted according to the chimney draught. In this way, all stoves are suited to every chimney and draught. The baffle plate is automatically opened when the window is slid open, so that no smoke escapes into the living room. The plate may be adjusted in 2 ways. 2.9.1.1 FIRST SETTING: ANGLE BAFFLE PLATE WITH CLOSED DOOR FIG. 9a door open FIG.
2.9.1.2 SECOND SETTING : Remove screws to adjust the moving plate nr 1 (fig 9e ) in sence of drough FIG. 9e IMPORTANT : IF YOU THINK THE DROUGHT IS NOT ENOUGH AND YOU HAVE SOME SMOKE RETURN IN THE LIVINGROOM, THEN YOU HAVE TO CHECK FIRST POINTS 2.9.1.1 AND 2.9.1.2. THIS IS IMPORTANT BEFORE YOU DO ANY OTHER REGULATION.
2.9.2 SYSTEM WITH THREE DEFLECTORS AND TWO AUTOMATIC VALVES With a closed door (fig 10) , we have a minimal evacuation for the combustion gaz. The main valve is closed (fig.10) The second deflector has a valve too (fig.11). When opening the liftdoor, the main valve and the second valve in the second deflector are opening simultaniously (fig.11). The combustion gaz is going out quickly when the window is open and is not going into the livingroom. Fig.
IMPORTANT : THIS MUST BE DONE IF YOU DIDN’T FOUND SATISFACTION WITH 2.9.1.1 AND 2.9.1.2 Fig.12 Pic..13 ATTENTION : FOT THE LUNA 550V YOU DON’T FIND A PLATE nr 1a AND nr 3. THIS IS BECAUSE OF THE NARROW ARCHITECTURE OF THIS MODEL. IN ANY CIRCUMSTANCES THIS WILL NOT GIVE A BAD FUCNTION OF THE APPLIANCE. 2.9.3. SECUNDARY AIR FLOW FOR COMBUSTION At the top of the window, across the whole witdh, a secondary air flow for combustion is provided.
2.10 AUTOMATICALLY ADJUSTABLE DOUBLE PLATE (Luna Gold see-trough ) In the illustrated figure, the first lift door and the first plate will drive the second lift door and second plate. The lift doors have been provided with a mechanical transmission to drive the different plates.
3. FUNCTIONNING When burning this fireplace with a closed door, the air clapet with seal is closed and so the fire takes the air through the channel connected with the flexibel from outside. The air is then spread underneath the spoiler over the entire width of the fireplace. It is important to clean out the fireplace from the ashes and to free the space under the spoiler to let the air coming into the fireplace ( Pic.9 ). When the door is opened , the air clapet is also being opened.
4. GENERAL RECOMMENDATIONS The appliance must be connected to the flue pipe and tested before the material is cemented in. In order to ensure that the appliance functions optimally, one must insulate the hot air ducts completely, comply with the minimum of the diameter measurements for the hot air ducts and hot air vents and the chimney must be adjusted. Do not put any inflammable materials in the immediate vicinity of the stove.
5. GUARANTEE 5.1 TERMS AND ITEMS COVERED • 8 years’ guarantee on the general structure. • 2 years’ guarantee on the parts and on the baffle plate • 1 year’s guarantee on the fans and the speed variator. • No guarantee on glass, seals or Chamotflex plates 5.2 PROVISO This contract ceases to be valid if the instructions and guidelines of these operating instructions were not followed.
6.
7.
8.