LUNA 850 V / 550 V GOLD GAS LUNA 850 DV / 550 DV GOLD GAS INSTRUCTION FOR INSTALLATION AND USE English 11-2012 Passion for fire
V E RY I M P O R TA N T I N S T A L L A T I O N INSTRUCTIONS FOR THE M - D E S I G N GAS FIREPLACES T H E S U P P L I E R TA K E S N O RESPONSBILITY FOR ANY POSSIBLE DAMAGE, POOR WORKING APPLIANCES AND ACCIDENT AS A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N MAINTENANCE GAS FIREPLACE M-DESIGN THE M-DESIGN GAS FIREPLACES MUST BE CHECKED every 2 years and GET a MAINTENANCE. THIS IS ALSO TO MAINTAIN YOUR WARRANTY. IF THIS WILL BE NOT OBSERVED, THE WARRANTY FELL.
SUMMARY 1. GENERAL REMARKS............................................................... 2. CONNECTION........................................................................... 3. INSTALLING THE FIREPLACE.............................................. 3.1.1 Positioning the fireplace................................................... 3.1.2 Gas connection................................................................... 3.1.3 Electrical connection . .................................
OPEN AND CLOSE THE DOOR CLOSING OPEN KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW ( INSIDE AND OUTSIDE ), CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE.
1. GENERAL REMARKS This is a moulding of the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the impression of a real chimney fire. The gas with air-vent furnaces are based on the principle of natural extraction from the furnace, which eliminates flue gas outside and brings in air (oxygen) from outside the house which is necessary for combustion of the gas. It uses to this effect two concentric pipes.
3. INSTALLING THE FIREPLACE After having checked the appliance, you ready to install your appliance. This is done as follows 3.1.1 POSITIONING THE FIREPLACE Place the fireplace on a stable surface using the adjustable feet. Adjust the height of the fireplace by turning the bolt ( pic 1 ) The stove may not be placed direct ont the floor to allow natural convection. The appertures for the air supply ( IN ) is situated underneath the appliances.
3.1.2 GAS CONNECTION The appliances are standard delivered with a 1/2” gas solded connection ( fig. 1 ). It is always located at the left-hand side of the appliance. Make sure nothing remains in the gas lines, since this may easely lead to blockage. An approved gas valve should always be connected to the appliance, wich must be accesible at all time . For this you can use a acces door ( pic. 1 next page ).
Fig. 1 ROOF EXIT ( C31 ) TAB. 1 This is recommanded with a roof exit > 3m Ø 150/100 Appliance LUNA 850 V / 550 V LUNA 850 DV / 550 DV C (min) C (max) Restrictiion HR+ (as from 4m) 3m 3m 18m 18m Ø 60 Ø 60 TAB. 2 This is recommanded with a roof exit < 3m Ø 200/130 Appliance LUNA 850 V / 550 V LUNA 850 DV / 550 DV C (min) C (max) Restriction HR+ (as from 3m) 2m 2m 10m 9m Ø 60 Ø 60 FIG.
Fig. 2 ROOF EXIT VIA EXISTING CHIMNEY (C31S) USDHC10 ou/of USDHC13 TAB. 1 150(min) Aplliance LUNA 850 V / 550 V LUNA 850 DV / 550 DV Ø 100 C (min) C (max) Restriction HR+ (as from 4m) 3m 3m 18m 17m Ø 60 Ø 60 flex 100 ou 130mm TAB. 2 200(min) Appliance LUNA 850 V / 550 V LUNA 850 DV / 550 DV Ø 130 C (min) C (max) Restriction HR+ (as from 3m) 2m 2m 10m 9m Ø 60 Ø 60 * It is obligatory to use the sanitation set USSAN with placing. * This USSAN piece must be sealed at the roof.
Fig. 3 WALL EXIT (C11) Ø 150/100 with reduction USVK13 on the aplliance Appliance A (min) B (min) B (max) 1,25m 1,25 wall exit wall exit A+0,5m A 850 V / 550 V 850 DV / 550 DV Restriction HR+ Ø 75 Ø 75 Fig. 4 WALL EXIT (C11) (A) Ø 200/130 in combination with (B) Ø 150/100 after first curve Appliance FIG.
Ø 200/130 Appliance 850 V / 550 V 850 DV / 550 DV A (min) B (min) 1 11 wall exit wall exit Restriction HR+ Ø 75 Ø 75 B (max) A+8m A+7m 3° Pic. 5 Pic.6 IMPORTANT : BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION (pic.5) IN DIRECTION OF OUTLET. IT IS EVEN BETTER, WHEN POSSIBLE, TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING. ONLY THE OUTLET MUST BE INSTALLED LIKE PIC.
Fig. 5 ROOF EXIT with 90° bends Ø 150/100 with reduction USVK13 on the appliance Appliance A (min) B (max) C (min) (A+B+C ) max 850 V / 550 V 1,25 m A+C B-A 16m 850 DV / 850 DV 1,25 m A+C+0,5 B-A-0,5 15m Fig.
5. INSULATION AND FINISHING Please , follow this instruction. The appliance can overheat if you not apply those instructions. Errorcode F02 will appear ! Once installation is complete, the appliance can be fitted. Before doing so, check the tightness of the gas pipe one more time. Light the appliance and check that it is working: check the tightness of the gas pipe and the smoke pipe. Once you have checked everything, you can perform the final insulating and finishing operations.
6. CONVECTION CURRENT Please , follow this instruction. The appliance can overheat if you not apply those instructions. Errorcode F02 will appear ! The enclosure of the furnace must be provided with ventilation grills or openings allowing for the elimination of heat by convection. It is possible to have a convection kit fitted with the furnace. This system directs the heat inside the room by means of flexible tubes ( dia. 150 mm).
OUT OUT IN IN Design Grill ( OUTLET ) OR 4 dm² 2 dm² INLET INLET INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 15
YOU HAVE TO CONNECT AT LEAST TWO APPERTURES SITUATED AT THE TOP OF THE APPLIANCE. URES. THE STOVE MAY NOT BE PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR, WTHOUT THE FEETS. THIS TO ALLOW NATURAL CONVECTION. THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE. EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia.150MM (see pic. below). THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE. IN OTHER CASE YOU WILL HAVE ERRORCODE F02.
7. MOUNTING A 3-SIDED FRAME 3-sided frame pic 1 pic 3 pic 4 upper frame sideframe 2,25cm 4 sided frame (lower piece) pic 5 pic 6 Fireplace is delivered standard with 4sided frame 3,5cm, an upper and 2 sideframes ( see pic. 2 ) Before mounting the 3 sided frame, remove 4 sided frame ( lower piece ) by lift it carefully up. Pull out the upper frame and in second way the left and right sideframes.
8. PUTTING IN PLACE THE LOGS, DIAMOND, SAPPHIRE AND WHITE STONES • Please check that the pilot light is switched off and that the furnace has cooled down. • Move the window to the front by pulling it. The window tips open at 45°. • Arrange the materials supplied. In accordance with your order you will have either a set of logs, diamond, sapphire or white pebbles. There is an adequate supply of materials . Our appliance is approved with these materials, so please do not use other products.
LUNA 850V / 850DVGAS 13 12 10 1 2 4 8 9 1 3 6 7 4 14 5 3 7 6 5 8 11 1 11 2 9 12 10 13 INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS 14 M-DESIGN 19
LUNA 850V 850DV GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 20
LUNA 850 V GAS / GAZ Only for 850V with two burners Seulement pour appareil 850V avec deux brûleurs en escaliers INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 21
5 LUNA 550 V / 550 DV GAS 6 4 7 2 1 2 1 8 3 4 5 3 6 7 INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS 8 M-DESIGN 22
1 6 2 3 4 5 7 8 LUNA 550 V / 550 DV GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 23
9. FIRST-TIME USE The masonry and plaster surrounding a recently installed furnace hold a great deal of moisture, which must first evaporate before commissioning the appliance. If not, the plaster may crack or split. Ask your installer about the timescale to follow. The first time you use it, only make a moderate-sized fire. The first few times the furnace is used, an unpleasant odour may be apparent. It comes from the protective paintwork. These emissions are totally harmless.
11. STARTPILOT The M-Design Gas appliance are provided with “Constant startpilot”. After the first use or when the winterperiod is coming and you use the fireplace daily, you must let the startpilot switch ON. Don’t switch it off after each use. This startpilot avoids condensation in the fireplace and protects the whole appliance and even the electronic parts against humidity. This startpilot has a very low gasconsumption. 12.
13. SPECIFICATION SHEET LUNA 850 V / 850 DV Gold gas Type of Gas Category Category Type NATURAL GAS I2L I2H G25 C11 , C31 , BUTANE-PROPANE / LPG I2E+ I2E I3+ G20 C31S C11 , C31 , I3B/P G31 C31S C11 , C31 , G30 C31S C11 , C31 , Entry pressure (mbar) Burner pressure (mbar) 25 23.8 20 19,3 30 29 37 36 50 36 28-30 28,2 Consumption (m3/h) Burner injector Fr./Re.* Pilot light injector 1.132 0,789 0,344 0,389 0,389 0,295 6 x 0,80 / 6x0.75 38/33A 6 x 0,80 / 6 x 0,5 38/33A 6 x 0,6 0.
LUNA 550V / DV GOLD gas Type of Gas Category Category Type /Type NATURAL GAS I2H I2L G25 C11 , C31 , BUTANE-PROPANE / LPG I2E+ I2E I3+ G20 C91 C11 , C31 , I3B/P G31 C91 C11 , C31 , G30 C91 C11 , C31 , C91 Entry pressure (mbar) Burner pressure (mbar) 25 23,28 20 19,1 30 29 37 36 50 36 28-30 28,2 Consumption (m3/h) Burner injector Fr./Re.* Pilot light injector 1,132 1,026 0,344 0,389 0,389 0,295 6x0,85 38/33A 6x0,85 38/33A 6x0,50 0.20P3 6x0,50 0.20P3 6x0,50 0.20P3 6x0,50 0.
LUNA 850 V GOLD GAS * connection gas on the left side * * 850V with one burner ( saphir, diamon, white stones ) 850V with two burner ( woodset ) INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 28
LUNA 850 DV GOLD GAS * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 29
LUNA 550 V GOLD GAS * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 30
LUNA 550 DV GOLD GAS * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 31
Example how to mount with a 4-sided frame Two flexible tubes can be connected to one design grid ( 2 connections ) Connecting Flex tubes 700H/ 1000H/1150H/1300H : 2x ( obliged) 1600H : 4 x ( obliged ) / 1900H : 6x (obliged) Inlet convection: OBLIGED ! Minimum distance to wich can be mounted TYPE 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV 2 Min. 5mm 2 3 Min. 4cm Min.
Example how to mount without a 4-sided frame Two flexible tubes can be connected to one design grid ( 2 connections ) Connecting Flex tubes 700H/1000H/1150H/1300H : 2x ( obliged) 1600H : 4 x ( obliged ) / 1900H : 6 x (obliged) 4-sided frame 3,5 - 7 or 10 cm Inlet convection: OBLIGED ! TYPE 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV Min. 5mm Min. 4cm Min.
4-sided frame 35 Z 4th -side frame X X = 3,5 cm TYPE 70 DETAIL Z onderlat / baguette X = 7 cm 105 X = 10,5 cm TYPE 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV A 631 931 1081 1231 1531 1831 481 781 B 431 431 431 431 431 431 485 931 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV A 623 923 1073 1223 1523 1823 473 773 C 401 401 401 401 401 401 661 901 INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 34
14.
14.
15. GUARANTEE This page is your warranty card. The guarantee is only valid for faults caused by construction defects or defects in the parts used to build the furnace. M-Design offers a 12 month guarantee on all electronic parts and a 8 year guarantee on the furnace construction. 8 Caution: The following items are always excluded from the guarantee: The glass, door, joints and internal decor.
16. IDENTIFICATION BOARDS 0461/2010 BN M-DESIGN MN LUNA 550V Gold C PN 0461BS0880 Serie N° GC P Qn(Hi) kW Pn (Hi) kW V m³/h 0461/2010 BN M-DESIGN MN LUNA 550DV Gold C PN 0461CL0981 Serie N° GC P Qn(Hi) kW Pn (Hi) kW V m³/h BE/FR I2E+ G20/G25-20/25mbar 6.5 5.6 1.026 BE/FR I2E+ G20/G25-20/25mbar 6.5 5.6 1.026 DE/LU/PL I2E G20 - 20 mbar 6.5 5.6 1.026 DE/LU/PL I2E G20 - 20 mbar 6.5 5.6 1.026 NL I2L G25 - 25 mbar 6.2 5.3 1.132 NL I2L G25 - 25 mbar 6.2 5.
0461/2010 BN M-DESIGN MN LUNA 850V Gold C PN 0461BS0880 Serie N° GC P Qn(Hi) kW Pn (Hi) kW V m³/h BE/FR I2E+ G20/G25-20/25mbar 9.7 8.4 1.026 DE/LU/PL I2E G20 - 20 mbar 9.7 8.4 1.026 NL I2L G25 - 25 mbar 9.2 8 1.132 AT/CH/CY/CZ/DK/ EE/ES/FI/GB/GR/ IE/IT/LT/LV/NO/ PT/RO/SE/SI/SK I2H G20 - 20 mbar 9..7 8.4 1.026 BE/CH/CY/CZ/ES/ FR/GB/GR/IE/IT/ LT/PT/SI I3+ G30/G31(28-30)/37mbar 9.5 7 0.389 CY/DK/EE/HU/IT/ LT/NL/NO/SE/SI/ SK/RO/TR/BG/IS/ LU/MT I3B/P G30 - 30 mbar 9.
17.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 550V - 550DV - 850V - 850DV GOLD - GAS M-DESIGN 41