Operation Manual
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
10
USVK13
REDUCTION 200/130 →150/100
PIC. 3 WALL EXIT (C
11
)
PIC. 4 WALL EXIT (C
11
)
0,25
min 1m
A min* = 0,25m
(USVK13)
+ 1m
PIC. 3
Not suitable for
1600 DH/CL/CR/DC
Ø 150/100
WITH REDUCTION USVK13 ON THE APPLIANCE (FIG. 3 )
Appliance A (min) B (min) B (max) Restriction HR+
1000 DH/CL/CR/DC
1,25*m wall exit =A+0,5m
Ø 75
1150 DH
1,25*m wall exit =A
Ø 75
1300 DH/CL/CR/DC
1,25*m wall exit = A
Ø 75
(A) Ø 200/130 in combination with (B) Ø 150/100
WITH REDUCTION USVK13 AFTER 90° CURVE ON HORIZONTAL PART ( FIG. 4 )
Appliance A (min)
Ø 200/130
B (min)
Ø 150/100
B (max)
Ø 150/100
Restriction HR+
1000 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +5m
Horiz. < 2m : Ø 75
1150 DH
1,25m wall exit A+ ”USVK13” +4m
Horiz. < 2m : Ø 75
1300 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +2,5m
Horiz. < 1m : Ø 75
1600 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +0,5m
----------
PIC. 4
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner