Operation Manual

LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
14
The enclosure of the furnace must be provided with ventilation grills or openings allowing for the
elimination of heat by convection. It is possible to have a convection kit ed with the furnace. This
system directs the heat inside the room by means of exible tubes ( dia. 150 mm).
It is obligatory to open at least 2 hot air vents ( for the LUNA 1600 you must open 4) at the top of the
appliance.
For the purposes of the installation of these ducts it is best to go vertically upwards rst for at least 1m
and then to change direction, making a rather wide bend and avoid using a ue terminal grid with
a small clearance because the speed loss that this causes reduces the eciency of the hot air vents.
Place all the ings that you use at the same lengths and angles if possible, otherwise it is possible
that some grids give o more heat than others and, seeing that a hot air pipe functions in a manner
similar to a chimney, the one that is hot rst has the most draught and therefore becomes hot even
more quickly.
Note: a circulation of hot air requires that no under-pressure be created in the room. A grid that is
near the oor (pic 2) sees to it that cold air can be drawn in.
M-design has developed its ideal hot air grids which have many advantages (pic. 1 & 2) and for the
elimination of hot air and the entry of warm air we advise you to use those Design grills made by
M-Design.
The appertures for the air supply “IN” (pic.2) is situated underneath the appliances. The stove may
not be placed direct ont the oor to allow natural convection.
To simplify the mounting of the grids you can use the corner prole (a) wich is furnished with the
grid. This prole is can be mounted on the side of the grid (two lile wholes en screws are provided).
.
6. CONVECTION CURRENT
Please , follow this instruction. The appliance can overheat if you not apply those instructi-
ons. Errorcode F02 will appear !