LUNA 700- 1000-1150-1300-1600-1900 H GOLD GAS INSTRUCTION FOR INSTALLATION AND USE UK 11-2012 1
V E RY I M P O R TA N T I N S T A L L A T I O N INSTRUCTIONS FOR THE M - D E S I G N GAS FIREPLACES T H E S U P P L I E R TA K E S N O RESPONSBILITY FOR ANY POSSIBLE DAMAGE, POOR WORKING APPLIANCES AND ACCIDENT AS A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N MAINTENANCE GAS FIREPLACE M-DESIGN THE M-DESIGN GAS FIREPLACES MUST BE CHECKED every 2 years and GET a MAINTENANCE. THIS IS ALSO TO MAINTAIN YOUR WARRANTY. IF THIS WILL BE NOT OBSERVED, THE WARRANTY FELL.
SUMMARY 1. GENERAL REMARKS............................................................... 5 2. CONNECTION........................................................................... 5 3. INSTALLING THE FIREPLACE.............................................. 3.1.1 Positioning the fireplace................................................... 3.1.2 Gas connection................................................................... 3.1.3 Electrical connection . .........................
OPEN AND CLOSE THE DOOR CLOSING OPEN KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW ( INSIDE AND OUTSIDE ), CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE.
1. GENERAL REMARKS This is a moulding of the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the impression of a real chimney fire. The gas with air-vent furnaces are based on the principle of natural extraction from the furnace, which eliminates flue gas outside and brings in air (oxygen) from outside the house which is necessary for combustion of the gas. It uses to this effect two concentric pipes.
3. INSTALLING THE FIREPLACE After having checked the appliance, you ready to install your appliance. This is done as follows 3.1.1 POSITIONING THE FIREPLACE Place the fireplace on a stable surface using the adjustable feet. Adjust the height of the fireplace by turning the bolt ( pic 1 ) The stove may not be placed direct ont the floor to allow natural convection. The appertures for the air supply ( IN ) is situated underneath the appliances.
3.1.2 GAS CONNECTION The appliances are standard delivered with a 1/2” gas solded connection ( fig. 1 ). It is always located at the left-hand side of the appliance. Make sure nothing remains in the gas lines, since this may easely lead to blockage. An approved gas valve should always be connected to the appliance, wich must be accesible at all time . For this you can use a acces door ( pic. 1 next page ).
PIC. 1 ROOF EXIT ( C31 ) TAB. 1 This is recommanded with a roof exit > 3m Ø 150/100 C (min) 3m C (max) 18m 1150 H 3m 18m Restriction HR+ (as from 4m) Ø 60 as from 2 m : Ø 75 Ø 60 1300 H 3m 18m Ø 60 1600 H / 1900 H 3m 20m Ø 75 Appliance 700 H / 1000 H TAB.
PIC. 2 ROOF EXIT VIA EXISTING CHIMNEY (C91) TAB. 1 Ø 150 (min) / Ø 100 C (min) C (max) Restriction HR+ (as from 4m) 700 H / 1000 H 1150 H 3m 3m 18m 18m Ø 60 Ø 60 1300 H 3m 18m Ø 60 1600 H / 1900 H 3m 20m Ø 75 Appliance TAB. 2 Ø200(min) / Ø 130 C (min) C (max) Restriction HR+ (as from 3m) 700 H / 1000 H 1150 H 1300 H 2m 2m 2m 10m 10m 10m Ø 60 Ø 60 Ø 60 1600 H / 1900 H 2m 12m Ø 75 Appliance It is obligatory to use the sanitation set USSAN with placing.
Pic. 3 WALL EXIT (C11) Ø 150/100 WITH REDUCTION USVK13 ON THE APPLIANCE (FIG. 3 ) Appliance A (min) B (min) B (max) Restriction HR+ 700 H /1000 H 1,25*m wall exit =A+1m Ø 75 1150 H 1,25*m wall exit =A+0,5m Ø 75 1300 H 1,25*m wall exit =A Ø 75 PIC. 4 WALL EXIT (C11) (A) Ø 200/130 in combination with (B) Ø 150/100 WITH REDUCTION USVK13 AFTER 90° CURVE ON HORIZONTAL PART ( FIG.
Ø 200/130 Appliance A (min) B (min) Restriction HR+ B (max) 700 / 1000 H 1m wall exit Ø 70 A+8m 1150 H 1m wall exit Ø 75 A+7m 1300 H 1m wall exit Ø 75 A+6m 1600 H 1m wall exit Ø 90 A+4m 1900 H 1m wall exit Ø 90 A + 2m A B 3° Pic.5 Pic. 6 IMPORTANT : BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION (pic.5) IN DIRECTION OF OUTLET. IT IS EVEN BETTER, WHEN POSSIBLE, TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING.
Pic. 5 ROOF EXIT with 90° bends Ø 150/100 WITH REDUCTION USVK13 ON APPLIANCE Aplliance 700/1000 H 1150 H A (min) 1,25* m 1,25* m B (max) A+C+0,5m A+C+0,5 C (min) B-A-0,5m B-A-0,5 (A+B+C )max 18m 17m 1300 H 1,25* m A+C B-A 16m 1600 H 1900 H 1,25* m 1,25*m A+C-0,5m A+C-1m B-A+0,5m B-A+1m 16m 14m Pic.
5. INSULATION AND FINISHING Please , follow this instruction. The appliance can overheat if you not apply those instructions. Errorcode F02 will appear ! Once installation is complete, the appliance can be fitted. Before doing so, check the tightness of the gas pipe one more time. Light the appliance and check that it is working: check the tightness of the gas pipe and the smoke pipe. Once you have checked everything, you can perform the final insulating and finishing operations.
6. CONVECTION CURRENT Please , follow this instruction. The appliance can overheat if you not apply those instructions. Errorcode F02 will appear ! The enclosure of the furnace must be provided with ventilation grills or openings allowing for the elimination of heat by convection. It is possible to have a convection kit fitted with the furnace. This system directs the heat inside the room by means of flexible tubes ( dia. 150 mm).
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 15 2 dm² Inlet Grid convection air Design Grid ( outlet ) with 2 connections INLET CONVECTION OUTLET CONVECTION OR Pic.
YOU HAVE TO CONNECT AT LEAST TWO APPERTURES SITUATED AT THE TOP OF THE APPLIANCE. FOR THE LUNA 1600, YOU MUST CONNECT 4 APPERTURES. THE STOVE MAY NOT BE PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR, WTHOUT THE FEETS. THIS TO ALLOW NATURAL CONVECTION. THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE. EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia.150MM (see pic. below). THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE.
7. MOUNTING A 3-SIDED FRAME 3-sided frame pic 1 upper frame sideframe 2,25cm 4 sided frame (lower piece) pic 2 Fireplace is delivered standard with 4sided frame 3,5cm, an upper and 2 sideframes ( see pic. 2 ) Before mounting the 3 sided frame, remove 4 sided frame ( lower piece ) by lift it carefully up. Pull out the upper frame and in second way the left and right sideframes. Take the left and right side of the 3 sided frame ( 3,5 - 7 or 10 cm ) and slide them in the notches ( see pic 4 ).
8. PUTTING IN PLACE THE LOGS, DIAMOND, SAPPHIRE AND WHITE STONES • Please check that the pilot light is switched off and that the furnace has cooled down. • Move the window to the front by pulling it. The window tips open at 45°. • Arrange the materials supplied. In accordance with your order you will have either a set of logs, diamond, sapphire or white pebbles. There is an adequate supply of materials . Our appliance is approved with these materials, so please do not use other products.
9 6 4 7 5 3 4 3 7 2 1 LUNA 1000 H GAS 9 8 1 8 2 5 6 INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 19
LUNA 1000 H GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 20
6 9 4 8 5 2 3 6 5 3 4 7 2 1 LUNA 1150 H GAS 9 8 1 7 INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 21
LUNA 1150 H GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 22
7 10 6 9 12 5 8 7 12 2 9 6 3 4 10 5 8 1 4 2 3 1 11 11 LUNA 1300 H GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 23
LUNA 1300 H GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 24
13 7 6 3 9 8 10 9 11 12 5 12 13 2 11 8 4 10 2 7 3 4 1 LUNA 1600 H GAS 5 1 6 INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 25
LUNA 1600 H GAS INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 26
9. FIRST-TIME USE The masonry and plaster surrounding a recently installed furnace hold a great deal of moisture, which must first evaporate before commissioning the appliance. If not, the plaster may crack or split. Ask your installer about the timescale to follow. The first time you use it, only make a moderate-sized fire. The first few times the furnace is used, an unpleasant odour may be apparent. It comes from the protective paintwork. These emissions are totally harmless.
11. STARTPILOT The M-Design Gas appliance are provided with “Constant startpilot”. After the first use or when the winterperiod is coming and you use the fireplace daily, you must let the startpilot switch ON. Don’t switch it off after each use. This startpilot avoids condensation in the fireplace and protects the whole appliance and even the electronic parts against humidity. This startpilot has a very low gasconsumption. 12.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 29 G20 86,4 6.8 6,1 5 1 Nominal Charge (KW) Charge (KW) NOX-emmission classe Cat. Rendement CE / 1 7 6,4 5 86,8 6 x 0,85 38/33A 6 x 0,85 38/33A Rendement (%) 0,789 0,870 C91 I2E Consumption (m3/h) Injector burner Injector startpilot C11 , C31 , I2E+ 20 19,3 C91 I2L 25 24,2 C11 , C31 , G25 I2H NATURAL GAZ 2 6,5 4,7 5 73 6 x 0,6 0.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 30 G20 85 8 6.8 5 1 Nominal Charge (KW) Charge (KW) NOX-emmission classe Cat. Rendement CE / 1 8.2 7 5 85.5 6 x 0.95 38/33A 6x1 38/33A Rendement (%) 0.868 0.985 C91 I2E Consumption (m3/h) Injector burner Injector startpilot C11 , C31 , I2E+ 20 19.1 C91 I2L 25 23.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 31 G20 9.3 8,0 5 1 Nominal Charge (KW) Charge (KW) NOX-emmission classe Cat.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 32 G20 10,7 8.9 5 1 Nominal Charge (KW) Charge (KW) NOX-emmission classe Cat. Rendement CE / 1 11.5 9.7 5 84 6 x 1,25 38/33A 6 x 1,25 38/33A 83 1.217 C91 I2E 1.
LUNA 700 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 33
LUNA 1000 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 34
LUNA 1150 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 35
LUNA 1300 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 36
LUNA 1600 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 37
LUNA 1900 H GOLD gas * connection gas on the left side * INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 38
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 39 Min. 4cm Min. 5mm 2 3 Min.
INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 40 Min. 4cm Min.
X = 10,5 cm X = 7 cm X = 3,5 cm 105 70 35 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV TYPE A 631 931 1081 1231 1531 1831 481 781 onderlat / baguette 4th -side frame Z B 431 431 431 431 431 431 485 931 C 401 401 401 401 401 401 661 901 DETAIL Z X 700H 1000H/DH 1150H/DH 1300H/DH 1600H/DH 1900 H 550V/DV 850V/DV TYPE A 623 923 1073 1223 1523 1823 473 773 4-sided frame INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS 41
14.
14. GUARANTEE This page is your warranty card. The guarantee is only valid for faults caused by construction defects or defects in the parts used to build the furnace. M-Design offers a 12 month guarantee on all electronic parts and a 8 year guarantee on the furnace construction. Caution: The following items are always excluded from the guarantee: The glass, door, joints and internal decor.