INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS
10
Pic. 3 WALL EXIT (C
11
)
PIC. 4 WALL EXIT (C
11
)
Ø 150/100
WITH REDUCTION USVK13 ON THE APPLIANCE (FIG. 3 )
Appliance A (min) B (min) B (max) Restriction HR+
700 H /1000 H
1,25*m wall exit =A+1m
Ø 75
1150 H
1,25*m wall exit =A+0,5m
Ø 75
1300 H
1,25*m wall exit = A
Ø 75
(A) Ø 200/130 in combination with (B) Ø 150/100
WITH REDUCTION USVK13 AFTER 90° CURVE ON HORIZONTAL PART ( FIG. 4 )
Appliance A (min)
Ø 200/130
B (min)
Ø 150/100
B (max)
Ø 150/100
Restriction HR+
700 H / 1000 H
1,25m wall exit A+ ”USVK13” +6m
Horiz. < 2m : Ø 75
1150 H
1,25m wall exit A+ ”USVK13” +5m
Horiz. < 2m : Ø 75
1300 H
1,25m wall exit A+ ”USVK13” +3,5m
Horiz. < 1m : Ø 75
1600 H
1,25m wall exit A+ ”USVK13” +1m
----------
USVK13
REDUCTION 200/130 →150/100
0,25
min 1m
A min* = 0,25m
(USVK13)
+ 1m
PIC. 3
Not suitable for
1600 DH/CL/CR/DC
and 1900H
PIC. 4
Not suitable for
1900H