INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
The grids are provided with two connections. 2 exibles for one grid !
Two holes between the two connection provides ventillation in the
maconry.
To simplify the mounting of the grids you can use the corner prole wich
is furnished with the grid. This prole is can be mounted on the side of
the grid (two lile wholes en screws are provided).
Note: a circulation of hot air requires that no under-pressure be created
in the room. A grid that is near the oor (pic 7d) sees to it that cold air
can be drawn in. Don’t connect those with a exible. Air will nd the
way to get at the right place. Place all the ings that you use at the
same lengths and angles if possible, otherwise it is possible that some
grids give o more heat than others and, seeing that a hot air pipe func
-
tions in a manner similar to a chimney, the one that is hot rst has the
most draught and therefore becomes hot even more quickly.
2.7 FAN
2.7.1 Installation
Remove the Chamotex plates, the boom plates and the opening to
the fan. See pic.8.
• Now slide the fan downwards to just under the stove.
• Make the necessary electrical connections.
2.7.2 Fan dimmer
•Leave the adjustment of the fan speed closed.
• Fuse 1.5A (Take the knob o, unscrew the lile plate, take it
out if it is to be replaced.)
• The adjustment screw for the minimum speed is under the knob.
(M-design has developed a new induction dimmer which lets the fan run
noiselessly and which may be bought as an option.)
• The fan (optional) may be started after the re has burned for 15 minu-
tes.
• Let the fan turn at the maximum speed for 12 hours the rst time to let
it run in.