Operation Manual
INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
2.8 FLUE
2.8.1 Flue
The construction of chimney must comply with strict conditions:
All the Luna stoves have a standard ue opening of 250 mm. in diameter. Certain chimney
congurations may require dierent standard diameters. In that case, look at table for the
height of the ue and the possibility of reducing the diameter with the help of a reduction piece.
Note : per 45° change of direction, one must keep to within 1m of this table.
• The ue must be thermally insulated.
The opening into the ue and its position are very important.
• One individual ue does not have more than two changes of direction.
The angle of the corner of these changes of direction may not be greater than 45 ° with the
perpendicular.
• The existing obstacles in the vicinity of the opening into the ue must be taken into account.
• Do not connect more than one stove to a chimney ue.
Table N°2 / MINIMUM HEIGHT OF THE FLUE IN TERMS OF ITS REDUCTION.
ø 300 ø 250 ø 200 ø 180
Luna Gold 700 H+ ----- > 4m > 7m
Luna Gold 850 H+ ----- ≥ 4m > 4m > 7m
Luna Gold 1000 H+ ----- ≥ 4m > 5m -----
Luna Gold 1150 H+ ----- ≥ 4m > 6m -----
Luna Gold 1300 H+ ----- ≥ 5m > 8m -----
Luna Gold 550 V+ ----- ≥ 4m > 4m > 7m
Luna Gold 850 V+ ----- ≥ 4m > 7m -----
Luna Gold 1000 V+ ----- ≥ 4m > 8m -----
Luna Gold 1150 V+ ----- > 5m -----
Luna Gold 1150 DH+ ≥ 5 m > 7m ----- -----
Luna Gold 1000 DV+ ≥ 5 m > 8m ----- -----
Luna Gold 850 DH+ ----- ≥ 5m > 7m -----
Luna Gold 850 DV+ ----- ≥ 5m > 8m -----
13