Operation Manual

INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE
A very essential point when seing up the Luna Gold is that the distance has to be respected
inbetween replace and the nishing material for the mantlepiece such as marble, gipsum,...
For this, a small bended metal sheet that is provided ont the replace ( pic.1 ) , is to be used as the
minimal reference for the distance. The nishing can only ga oas far as this meteal sheet ( pic.2 ).
Don’t remove this ( pic.3 ) ! This allows you to take out the 4th side frame and to let the airow in
the mantlepiece for natural convection.
2.3 INSULATION AND FINISHING
Once installation is complete, the appliance can be ed. Once you have checked everything, you
can perform the nal insulating and nishing operations.
The built-in part of the furnace tends to be very warm. Please check that the furnace is not too
narrowly ed and that there is adequate space for the elimination of hot air. For insulation of the
furnace, we advise you to use M Design insulating plates. You are advised against using any other
insulation product. Inammable materials as well may not be used for the nishing.
Please , follow this instruction. The appliance can overheat if you not apply those in-
structions.
Pic. 2
Pic. 3
min. 5 mm
The masonry must be raised around the furnace. Because of the expansion
of the furnace during combustion, an interstice of at least 5 mm must be
provided on each side of the appliance. The masonry must not lean against
the furnace.
THE APPLIANCE MUST BE SET FREE .
Please pay aention to leave approx. 2 mm inbetween the nishing frame
and maconry ( see p.17 , mounting a 3-sided frame )
Pic. 1