Operation Manual
INSTRUCTION FOR INSTALLATION AND USE LUNA GOLD+ WOOD
REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE
A very essential point when seing up the Luna Gold is that the distance has to be respected
inbetween replace and the nishing material for the mantlepiece such as marble, gipsum,...
For this, a small bended metal sheet that is provided ont the replace ( pic.1 ) , is to be used as the
minimal reference for the distance. The nishing can only ga oas far as this meteal sheet ( pic.2 ).
Don’t remove this ( pic.3 ) ! This allows you to take out the 4th side frame and to let the airow in
the mantlepiece for natural convection.
2.3 INSULATION AND FINISHING
Once installation is complete, the appliance can be ed. Once you have checked everything, you
can perform the nal insulating and nishing operations.
The built-in part of the furnace tends to be very warm. Please check that the furnace is not too
narrowly ed and that there is adequate space for the elimination of hot air. For insulation of the
furnace, we advise you to use M Design insulating plates. You are advised against using any other
insulation product. Inammable materials as well may not be used for the nishing.
Please , follow this instruction. The appliance can overheat if you not apply those in-
structions.
Pic. 2
Pic. 3
min. 5 mm
The masonry must be raised around the furnace. Because of the expansion
of the furnace during combustion, an interstice of at least 5 mm must be
provided on each side of the appliance. The masonry must not lean against
the furnace.
THE APPLIANCE MUST BE SET FREE .
Please pay aention to leave approx. 2 mm inbetween the nishing frame
and maconry ( see p.17 , mounting a 3-sided frame )
Pic. 1
7