Multi Level Software Locks EM2050 EM3050 EM3550 User manual V01 EN M•LOCKS BV Vlijtstraat 40 • 7005 BN Doetinchem • The Netherlands • www.m-locks.
www.m-locks.
Multi Level Software Locks V01 EN CONTENT INSTRUCTIONS FOR USE 1 Important instructions 2 Symbols and signals 3 Opening in standard mode 4 Opening with dual combo 5 Opening with time delay 6 Changing code 7 Activating silent alarm MANAGER INSTRUCTIONS 8 Activating users 9 Activating users with dual mode 10 Activating users with Dallas key 11 Disabling / enabling users not active in dual mode 12 Deleting users 13 Deleting users in dual mode 14 Setting the time delay and open window time8 1
1 IMPORTANT INSTRUCTIONS • Before using the lock, please read the instructions for use carefully. • The instructions for use only relate to the lock itself and not to how to operate the safe. • Ensure that you only program the lock while the safe door is open. • After changing the code, always try the code several times with the safe door open. • Only after several positive function tests (opening / closing) the safe door may be closed. • Each key entry is confirmed by an audible tone and visual signal.
Multi Level Software Locks V01 EN ! Caution! • The lock has been designed for use in a temperature range from +10˚C to +50˚C and a noncondensing humidity range from 30% to 80%. • It may only be cleaned with a moist cloth (do not use aggressive cleaning agents). • The lock may only be installed by qualified fitters. • The lock may not be lubricated. • Never open the lock housing. If it is necessary to disassemble the hardware, only do so in accordance with the technical instructions.
After entering a right code at the EM3050 the bolt will be retracted. Depending on the programming of the EM3050 the lock will close automatically after 5 seconds or push a random key to close (PTC = Push To Close). 4 OPENING WITH DUAL COMBO For example! 1 and and 2 1 1 1 1 1 2 2 2 2 2 Two users are required to open with dual combo. For example 1-1-1-1-1-1 and 2-2-2-2-2-2. EM2050: Enter codes (i.e. 1-1-1-1-1-1 and 2-2-2-2-2-2).
Multi Level Software Locks V01 EN During the open window, the light flashes and the locks beeps, every second. To open the lock, a valid code has to be entered again during the open window. After entering a right code, you will hear a double tone. You can unlock the door. If the lock is not opened within 3 seconds, the lock will automatically lock again. If the open window expires without entering a valid code, the lock is secured again with time delay.
7 ACTIVATING SILENT ALARM If, by set up, silent alarm is programmed and the lock is connected to an alarm system. For example! 2 2 2 2 2 3 In case of a hold up situation, a silent alarm can be sent by entering the last digit + 1. If the last number is a 9, you have to enter 0, to send a silent alarm. For example: Valid code 2-2-2-2-2-2, alarm will be sent by entering: 2-2-2-2-2-3. This code works as a valid code. The silent alarm is indiscernibly for an outsider. 8 www.m-locks.
Multi Level Software Locks V01 EN MANAGER INSTRUCTIONS ACTIVATING USERS 8 1 Press and hold ‘1’ until you hear a double tone. The LED will illuminate when performing the following actions: For example! 9 8 7 6 5 4 • Enter your personal Manager Code 1 • Enter User ID 1-9 (only if more than 1 user is programmed) 1 1 1 1 1 1 • Enter the new User Code 1 1 1 1 1 1 • Enter the new User Code again 9 ACTIVATING USERS IN DUAL MODE (IF MANAGER IS IN DUAL MODE) Enter a random User Code.
2 • Enter User ID 1-9 (only if more than 1 user is programmed) 2 2 2 2 2 2 2 2 • Enter User Code 2 2 2 2 • Enter User Code again 10 ACTIVATING USER WITH DALLAS KEY Requirements: an installed entry unit with integrated Dallas reader and Dallas key. 1 Press and hold ‘1’ until you hear a double tone.
Multi Level Software Locks V01 EN 11 DISABLING /ENABLING USERS (NOT ACTIVE IN DUAL MODE) 2 Press and hold ‘2’ until you hear a double tone. The LED will illuminate when performing the following actions: For example! 9 8 7 6 5 4 • Enter your personal Manager Code All users are disabled. Please repeat this procedure to enable all users. 12 DELETING USERS 3 Press and hold ‘3’ until you hear a double tone.
3 Press and hold ‘3’ until you hear a double tone. The LED will illuminate when performing the following actions: For example! 9 8 7 6 5 4 • Enter your personal Manager Code 1 • Enter User ID of the user that has to be deleted The user has been deleted. To activate user again please refer to function “activate user”. 14 SETTING THE TIME DELAY AND OPEN WINDOW TIME Time delay: The time between the first and second code entry in minutes.
Multi Level Software Locks V01 EN 15 CHANGING THE DELAY SETTING AND OPEN WINDOW The delay setting can only be changed or deleted during the open window time. For example! 1 1 1 1 1 1 Enter a valid code. Time delay starts, the light flashes. After the time delay period the open window time starts. The LED flashes 1x a second and beeps. 9 Press and hold ‘9’ until you hear a double tone.
1 2 3 4 5 6 7 8 9 0 • Enter 1, 2, 3, 4, 5, 6, 7, 8, 9, 0 to stop Double signal = active user with code One signal = active user without code (or disabled) Long signal = user not active For Example! 4 User 4 is an active user with code. 0 • Enter ‘0’ to end the user audit 17 LOCK AUDIT (ONLY IF 2 OR MORE USERS ARE INSTALLED) For auditing a lock, entry unit with Dallas reader and Audit Pack for MLS locks are required. 7 Press and hold ‘7’ until you hear a double tone.
Multi Level Software Locks V01 EN Battery compartment in entry unit Open the battery compartment and replace the battery by a new one. Battery compartment inside the safe In case of keypads starting with ST40xx and DE20xx, the battery compartment is located inside the safe. If the battery is completely exhausted, hold a fresh battery pressed against the poles on the front of the keypad, while entering the code, until the lock opens completely. 19 TROUBLESHOOTING The lock does not react a.
M•LOCKS BV Vlijtstraat 40 • 7005 BN Doetinchem • The Netherlands • www.m-locks.