Technical data

WDL 2.5/S/
L/L
6/84.5/48.7
8 mm/M 2.5/3.5 x 0.6
400 V/24 A/2.5 mm
2
250/380
400 V/6 kV/3
0.4...0.7
1
0.5…4
1.5…4
0.5…4
0.25…4
0.25…4
A 3
20
20
300 V/15 A/22…12 AWG
300 V/10 A/26…12 AWG
W Cat.No. Qty.
103120 50
Type Cat.No. Qty.
WAP WDL 2.5/S
106770 20
TSch 1 031916 100
Q 2 107150 50
Q 3 105160 50
Q 4 107170 50
Q 10 107180 20
FW 6 046866 500
FS 6 046876 500
1/16
Terminals / accessoriesThree-way terminal blocks WDL 2.5/S/
NT/L/PE
Dimensions
Width/length/height (mm) with TS 32 Y
Width/length/height (mm) with TS 35 x 7.5 W
Insulation stripping length/clamping screw
VDE rated data 0611 Part 4/2.91
Rated voltage/rated current/rated cross-section
Rated insulation voltage VDE 0110/2.79/Insul. group C V~
Rated voltage/impulse voltage VDE0110/1.89 /pollution severity
Further technical dates
Tightening torque range Nm
Torque setting with DMS2 electric screwdriver
Clampable conductor
“e” solid H07V-U mm
2
“m” stranded H07V-R mm
2
“f” flexible H07V-K mm
2
“f” flexible H07V-K and AEH DIN 46 228/1 mm
2
“f” flexible H07V-K and AEH with plastic insul. collar. mm
2
Gauge pin to 947-1 Size
Continuous current rating of cross-connection 2-poles A
Continuous current rating of cross-connection multipole A
UL/CSA rated data
Voltage/current/conductor size UL
Voltage/current/conductor size CSA
Ordering data Version
yellow-green/blue/dark beige Wemid
yellow-green/dark beige Wemid
blue/dark beige Wemid
dark beige Wemid
End plate
Support plate
WHP for SSch 10 x 3
Wemid blue
thickness 1.5 mm
Small partition
Cross-connection (L/N/NT)
Busbar 10 x 3
Cu 140 A
Ms 100 A
Clamping yoke
Supply for SSch 10 x 3
Neutral disconnect terminals
as supply terminals see page 2/12
Marking tags Print
Consecutive horizontal
Consecutive vertical
123456
Distance
WHP-WHP
max. 200 mm
6/84,5/48,7
8 mm/M 2,5/3,5 x 0,6
250V/400V/24 A/2,5 mm
2
250/380
250V/400 V/4 kV/3
0,4...0,7
1
0,5…4
1,5…4
0,5…4
0,25…4
0,25…4
A 3
20
20
300 V/15 A/22…12 AWG
300 V/10 A/26…12 AWG
W Cat.No. Qty.
103060 50
(NT connection
coded blue)
Type Cat.No. Qty.
WAP WDL 2.5/S
106770 20
WHP WDL 2.5/S
106798 20
TSch 1 031916 100
Q 2 107150 50
Q 3 105160 50
Q 4 107170 50
Q 10 107180 20
SSch 10 x 3 Cu034890 1 m
SSch 10 x 3 Ms025980 1 m
ZBE 6 K 052598 50
ZB 16 K 050288 50
ZB 35 K 050268 50
WNT 6 101088 50
WNT 10 101098 50
WNT 16 N 101900 50
WNT 70 N 951221 10
FW 6 046866 500
FS 6 046876 500
L
L
PE
NT
L
Installation specifications for power
systems up to 1000V to VDE 0100 (EC
364) require that the installed system be
subjected to an insulation measurement
test.Special specifications stipulate an
insulation measurement for all outgoing
conductors(L 1, L 2, L3, N) without
making any disconnections.The WDL
three-way terminal block meets these
requirements. Circuits can be connected
on three levels across a width of only 6
mm in a clear and space-saving manner.
Two independent terminal strips with
disconnect elements and a cross-
connection system of the N conductor are
available.
WDL 2.5/S…
N cross-connection with the proven 10x3
mm busbar system up to 140 A. The
busbar is fed by a separate clamping yoke
(ZB 4-ZB 16) or an N disconnect terminal
of the WNT series.
WDL 2.5/S/NT/L/PE
The disconnectable N connection is
connected to the 10x3 busbar at the
upper level or, in the second version, with
the WQV cross-connection system. The
individual levels are colour-coded to
facilitate circuit assignment. If no N
disconnection is required, additional three-
way terminals with feed-throughs for the N
conductor are available.
WDL 2.5/S/L/L
Three-phase circuits can be implemented
by combining 3-way terminals (L 1, NT,
PE) and WDL 2.5/(S)/L/L two-way
terminals (L 2, L 3).
Mounting rails, brackets, additional marking material and accessories please see relevant Catalogue Section