Technical data

WDL 2.5/L/L
6/90/48.7
8 mm/M 2.5/3**/3.5 x 0.6
400 V/24 A/2.5/4** mm
2
250/380
400 V/6 kV/3
0.4...0.7
1
0.5…4/6**
1.5…4/6**
0.5…4/6**
0.5…4/4**
0.5…4/4**
A 3/A 4**
20
40
300 V/15 A/22…12 AWG
300 V/10 A/26…12 AWG
W Cat.No. Qty.
103030 50
Type Cat.No. Qty.
WAP WDL 2.5 106780 20
TSch 1 031916 100
Q 2 107150 50
Q 3 105160 50
Q 4 107170 50
Q 10 107180 20
WQV 4/2 105196 50
WQV 4/3 105456 50
WQV 4/4 105466 50
WQV 4/10 105206 20
WAW 1 900450 1
FW 6 046866 500
FS 6 046876 500
1/18
WDL 2.5/NT/L/PETerminals/accessories
6/90/48.7
8 mm/M 2.5/3**/3.5 x 0.6
250V/400V/24 A/2.5/4** mm
2
250/380
250V/400 V/4 kV/3
0.4...0.7
1
0.5…4/6**
1.5…4/6**
0.5…4/6**
0.5…4/4**
0.5…4/4**
A 3/A 4**
20
40
300 V/15 A/22…12 AWG
300 V/10 A/26…12 AWG
W Cat.No. Qty.
102980 50
(N-connection coded blue)
Type Cat.No. Qty.
WAP WDL 2.5 106780 20
TSch 1 031916 100
Q 2 107150 50
Q 3 105160 50
Q 4 107170 50
Q 10 107180 20
WQV 4/2 105196 50
WQV 4/3 105456 50
WQV 4/4 105466 50
WQV 4/10 105206 20
WAW 1 900450 1
FW 6 046866 500
FS 6 046876 500
Dimensions
Width/length/height (mm) With TS 32 Y
Width/length/height (mm) With TS 35 x 7.5 W
Insulation stripping length/clamping screw
VDE rated data 0611 Part 4/2.91
Rated voltage/rated current/rated cross-section
Rated insulation voltage VDE 0110/2.79/insul. group C V~
Rated voltage/impulse voltage VDE0110/1.89/pollution severity
Further technical data
Tightening torque range Nm
Torque setting with DMS2 electric screwdriver
Clampable conductor
“e” solid H07V-U mm
2
“m” stranded H07V-R mm
2
“f” flexible H07V-K mm
2
“f” flexible H07V-K and AEH DIN 46 228/1 mm
2
“f” flexible H07V-K and AEH With plastic insul. collar mm
2
Gauge pin to 947-1 Size
Continuous current rating of cross-connection multipole A
Continuous current rating of cross-connectionWQV 4 multipole A
UL/CSA rated data
Voltage/current/conductor size UL
Voltage/current/conductor size CSA
Ordering data Version
Wemid
End plate
Small partition for Q…
Cross-connection (L. NT. N)
Cross-connection* Insert (L. NT. N)
32 A
Notching tool for WQV
Marking tags Print
Consecutive horizontal
Consecutive vertical
1 2 3 4 5 6
** For N-connection only (circuit breaker side)
Mounting rails, brackets, additional marking material and accessories please see relevant Catalogue Section
Installation specifications for power
systems up to 1000V to VDE 0100 (EC
364) require that the installed system be
subjected to an insulation measurement
test. Special specifications stipulate an
insulation measurement for all outgoing
conductors(L 1, L 2, L3, N) without
making any disconnections.The WDL
three-way terminal block meets these
requirements. Circuits can be connected
on three levels across a width of only 6
mm in a clear and space-saving manner.
WDL 2.5…
N-cross-connection via the WQV 4 cross-
connection system from the W series. The
supply power is fed directly via a clamping
yoke in the terminal.
WDL 2.5/NT/L/PE
The N connection can be disconnected in
the upper level by the WQV cross
connection system with which it is
connected. The separate levels are colour-
coded to facilitate wiring.
WDL 2.5/L/L
Three-phase circuits can be implemented
by combining 3-way terminals (L 1, NT,
PE) and WDL 2.5/(S)/L/L two-way
terminals (L 2, L 3).
Three Way
terminal blocks
PE
NT
L
*
L
L
*