Technical data

1/23
WTL 6/1/STBDisconnect test terminal blocks WTD 6/1
Dimensions
Width/length/height (mm) with TS 32 Y
Width/length/height (mm) with TS 35 x 7.5 W
Insulation stripping length/clamping screw
Rated data
Rated voltage/rated current/rated cross-section
Rated impulse voltage VDE 0110/1.89 /pollution severity
Further technical data
Tightening torque range Nm
Torque setting with DMS2 electric screwdriver
Clampable conductor
“e” solid H07V-U mm
2
“m” stranded H07V-R mm
2
“f” flexible H07V-K mm
2
“f” flexible H07V-K and AEH DIN 46 228/1 mm
2
“f” flexible H07V-K and AEH With plastic insul.collarmm
2
Gauge pin to 947-1 Size
Continuous current rating of cross-connection 2…5 pole A
Continuous current rating of cross-connection 6…10 pole A
UL/CSA rated data
Voltage/current/conductor size UL
Voltage/current/conductor size CSA
Ordering data Type
With socket Wemid
without socket Wemid
End plate/partition
thickness 1.5 mm
Small partition
Cross-connections
2-poles
3 poles
4 poles
10 poles
WKB
WKS
Socket
Disconnect lock
Prevents undesired opening of disconnector
Test plug
Marking tags Print
Consecutive horizontal
Consecutive vertical
1 2 3 4 5 6
Socket Type StB 25 accepts test plug PS 4 in Type WTL
6/1 disconnect terminals or Type QS cross-connection
plugs. The Type StB 35 is used to simultaneous testing
with inserted cross-connection slides (QVS).
Current transformers must always have a
closed secondary circuit, even when the
exchanging measuring instruments or
electricity meters and when carrying out
reference measurements with external
measuring instruments.
Various easy and clear wiring solutions
can be found using lateral disconnect
terminals WTL 6/1, feed-through terminals
WTD 6/1 and cross-disconnect terminals
WTQ 6/1.
Examples:
Simple current transformer circuits
Measurement transformer test sets
With one basic version, the WTL 6/2 can
fulfill all circuit tasks occurring in practice
as a lateral disconnect terminal. The short-
circuit slides are of shock-proof design.
Two short circuit slides can be installed.
The WTL 6/3 is identical in function with
the WTL 6/2 and is suitable for safety plug
use due to its test socket StB 19.1 which
is safe from finger touch.
Meter test with WTL 6/1
Combination of lateral disconnect terminal
and feed-through terminal (example).
8/65/52.2
8/65/48.2
12 mm/M 3.5/3*/4.0 x 0.8
500 V**/41 A/6 mm
2
6 kV/3
0.8...1.6/0.4...0.8*
3
0.5…10
1.5…10
0.5…10
0.5…6
0.5…6
A 5
(QL 2…5) 47
(QL 6…10) 36
600 V/45 A/20…8 AWG
W Qty. Y Qty.
101690 50 101700 50
101670 50 101680 50
Type Cat.No. Qty.
WAP WTL 106830 20
WTW WTL 106840 20
TSch 2 035366 100
QL 2 019430 50
QL 3 019440 50
QL 4 019450 50
QL 10 033830 20
BS M 3x20 Cu 037710 100
VH 12 024900 100
QS 2 027096 20
QVSK 2 167036 20
QVS 3 032930 20
QVS 4 030740 20
BS 25 bare 033470 100
VH 19 031800 100
StB 25 yellow 026720 50
StB 25 green 027120 50
StB 25 violet 027130 50
StB 35 green 038900 50
StB 35 green 038890 50
StB 35 violet 038910 50
StB 14 016990 50
SSP 3 053176 100
5PS 4 029960 20
FW 8 127696
FS 8 128966
8/65/52.2
8/65/48.2
12 mm/M 3.5/3*/4.0 x 0.8
400 V/41 A/6 mm
2
6 kV/3
0.8...1.6/0.4...0.8*
3
0.5…10
1.5…10
0.5…10
0.5…6
0.5…6
A 5
(QL 2…5) 47
(QL 6…10) 36
600 V/45 A/20…8 AWG
W Qty. Y Qty.
101710 50 101720 50
Type Cat.No. Qty.
WAP WTL 106830 20
WTW WTL 106840 20
TSch 2 035366 100
QL 2 019430 50
QL 3 019440 50
QL 4 019450 50
QL 10 033830 20
BS M 3x20 Cu 037710 100
VH 12 024900 100
QS 2 027096 20
QVSK 2 167036 20
QVS 3 032930 20
QVS 4 030740 20
BS 25 bare 033470 100
VH 19 031800 100
PS 4 029960 20
FW 8 127696
FS 8 128966
Mounting rails, brackets, additional marking material and accessories please see relevant Catalogue Section
* Disconnector
** 400 V as disconnect terminal