Technical Manual 1.05, C600 Professional Technical Manual M2M Control C600 Professional Version 1.
Technical Manual 1.05, C600 Professional Introduction This manual contains technical documentation allowing easy installation and use of the C600 Professional unit. For information on the programming and software configuration of the C600 Professional please refer to the M2M Control IDE (Integrated Development Environment) documentation. The C600 Professional is the first member belonging to the new M2M Control C-Series generation of powerful M2M units.
Technical Manual 1.05, C600 Professional Table of Contents Introduction ..........................................................................................................................2 Table of Contents ................................................................................................................3 Graphical view .....................................................................................................................4 External connections ............................
Technical Manual 1.05, C600 Professional Graphical view Page 4 of 24 M2M Control by Infranet Technologies GmbH Tempowerkring 2 21079 Hamburg Germany Ph: +49.40.69647-260 Fax: +49.40.69647-259 Email: info@m2mcontrol.de Web: www.m2mcontrol.
Technical Manual 1.05, C600 Professional External connections Overview Connections to external equipment are done via the connectors located back and forth on the product. All connections are available externally for easy access; this also includes SIM-Card and SD-Card. There are no user-serviceable parts inside and the warranty is void if the unit is disassembled. The front plate is equipped with connectors commonly accessed by the user (SIM-Card, SD-CARD, DIP-Switch, Headset, LED’s and RS232).
Technical Manual 1.05, C600 Professional Connector X1: 4 pin (Power) connector overview. Pin Name Description 1 SUPP Power supply, positive (+) connection 2 DI5/IGN Digital input 5 / Ignition input (Shared with 16 pin connector) 3 SUPP Power supply, positive (+) connection 4 PGND Power Ground Connector X2: 12 pin (Communication) connector overview.
Technical Manual 1.05, C600 Professional Connector X4: 6 pin (Serial port 1 / programming) connector overview. Pin Name Description 1 TD RS232 transmit data from Serial port 1 2 RS-Detect Programming cable detect, normally unconnected (if programming cable, connect to GND) 3 DC-Out +3.3V/150mA DC-Out for external equipment. (Shared with 12 pin connector) 4 RD RS232 receive data to Serial port 1 5 SGND Signal Ground 6 SGND Signal Ground RJ45 (Serial port 2) connector overview.
Technical Manual 1.05, C600 Professional Power supply The C600 Professional unit is to be supplied with 8..36 VDC from an external DC power source connected to the 4 pin power connector. Positive power is applied to the SUPP pin and ground is connected to the PGND pin. The connector has two “SUPP” supply pins as these also supplies power for the Digital Outputs. If the total current consumption on the digital outputs exceeds 1.5A then power must be applied to both pins.
Technical Manual 1.05, C600 Professional Digital outputs The digital outputs control four “high-side” switches. They function like a contact, where one side is connected to the positive supply of the C600 unit, and the other is the output. The switches are protected against short circuit, ESD and electronic kickback from inductive loads such as relays etc. The maximum switch-able inductance is 20mH and must not be exceeded.
Technical Manual 1.05, C600 Professional X3: 16 pin (I/O) connector overview. Pin Name Description 3 DIN 1 Digital input 1 11 DIN 2 Digital input 2 5 DIN 3 Digital input 3 13 DIN 4 Digital input 4 6 DIN 5/IGN Digital input 5 / Ignition input. (Shared with 4 pin connector) 4 SGND Signal Ground 10 SGND Signal Ground 14 SGND Signal Ground Page 10 of 24 M2M Control by Infranet Technologies GmbH Tempowerkring 2 21079 Hamburg Germany Ph: +49.40.69647-260 Fax: +49.40.69647-259 Email: info@m2mcontrol.
Technical Manual 1.05, C600 Professional Analog Inputs The analog inputs are voltage inputs with a range from 0V to 10V DC. The analog voltage is converted to a digital value with a resolution of 10bit or 1024 in decimal. The decimal value with 10V applied to the input is 1023 and 512 for 5V. The input signal is connected between AIN and AGND. AGND must be connected to the reference of the connected equipment. Please be aware that deviations may occur, as the system is very noise sensitive.
Technical Manual 1.05, C600 Professional X4: 6 pin (Serial port 1 / programming) connector overview. Pin Name Description 1 TD RS232 transmit data from Serial port 1 4 RD RS232 receive data to Serial port 1 2 RS-Detect Programming cable detect, normally unconnected (if programming cable, connect to GND) 5 SGND Signal Ground X2: 12 pin (Communication) connector overview.
Technical Manual 1.05, C600 Professional CAN The C600 Professional provides the physical layer for the CAN (Controller Area Network) serial communication interface in accordance with the ISO 11898 standard. The CAN bus is designed for high-speed (up to 1Mbit) robust communication in especially harsh environments like those found in the automotive industry.
Technical Manual 1.05, C600 Professional 1-Wire The 1-Wire bus is available on the 12 pin connector. All 1-Wire communication goes through this single pin and all 1-Wire devices connected to this pin retrieves its power directly from the bus (called parasitic power). By this only two wires are needed – the 1wire signal and the ground reference – allowing minimal cable installations. For 1-Wire IDButton readers, which include a built-in LED, a dedicated output is available for this purpose.
Technical Manual 1.05, C600 Professional Headset connector The C600 unit has a 4-pole 2.5mm jack connector for connecting a Nokia compatible headset to the built-in GSM modem. The speaker output is amplified through the internal amplifier and is a differential (balanced) signal. An audio line transformer must be used to convert the signal to a single ended signal, when connected to external equipment that does not have a differential (balanced) input.
Technical Manual 1.05, C600 Professional Installing the SIM-card The C600 Professional unit contains a standard SIM card reader. It is located on the front plate (please see the graphical view) and is easily accessed. The SIM card reader has a push/push eject system and a mechanical lock for secure installation of the SIM card. Orientate the card as showed below, and insert it into the card reader. Push the card into the reader until a click sound occurs – the card will now stay in its position.
Technical Manual 1.05, C600 Professional Installing the SD-CARD The C600 Professional unit has a standard SD-CARD reader with FAT file-system support for standard PC-compatibility. Up to 2 GByte capacity is supported. The SD-CARD features a Push/Push eject system for reliable insertion and operation. To insert a card into the reader orientate it as showed below, and push the card into the reader until a click sound occurs.
Technical Manual 1.05, C600 Professional Indicators (LED’s) Three bi-colored (red and green) and a single yellow LED indicators are present on the unit (see the graphical view). Two bi-colored indicators are available to the user and the remaining two LED’s are signaling the status and possible errors of the C600 unit. The user control LED one through four for application specific signaling purposes. LED 1 and 3 are green, and LED 2 and 4 is red.
Technical Manual 1.05, C600 Professional System LED 3 (GSM activity and “Wait For Event”) pattern overview. Pattern Operating Status Off The GSM module is turned off 600 ms On / 600 ms Off No SIM card inserted or no PIN code entered, or network search in progress, or ongoing user authentication, or network logon in progress. 75 ms On / 3 s Off Logged to the network. No call in progress. 75 ms On / 75 ms Off / A GPRS session is active 75 ms On / 3 s OFF Flashing Indicates GPRS data transfer.
Technical Manual 1.05, C600 Professional Internal Li-Ion battery The C600 Professional contains an internal Li-Ion battery for operation even during an external power fail. Making it possible to report power loses etc. Please note that when external power is removed the unit will by default be powered down. This setting can be changed though and is documented in the M2M Control IDE online manual.
Technical Manual 1.05, C600 Professional Specifications for the C600 Professional Page 21 of 24 M2M Control by Infranet Technologies GmbH Tempowerkring 2 21079 Hamburg Germany Ph: +49.40.69647-260 Fax: +49.40.69647-259 Email: info@m2mcontrol.de Web: www.m2mcontrol.
Technical Manual 1.05, C600 Professional Specifications for the 16-channel GPS receiver u-blox LEA-4A General: 16 Channels simultaneous operation DGPS capable L1 frequency (1575.42MHz) C/A code (Standard Positioning Service) Continuous tracking receiver Update Rate: NMEA @ 1 Hz Accuracy: Position DGPS/SBAS Acquisition: Autonomous Operation in Standard Sensitivity Mode Reacquisition <1 sec. Hot Start < 3.5 sec. Warm start 33 sec. Cold start 34 sec. Interface protocol: NMEA 0183 v3.
Technical Manual 1.05, C600 Professional Appendix A – Enabling the CAN bus Write capability Connecting the C600 to a CAN network can be dangerous. If the C600 is not configured with the correct network parameters, it can lead to network corruption and may interfere with other connected equipment on the bus. Especially in vehicles great precautions must be observed to prevent interruption of the communication.
Technical Manual 1.05, C600 Professional 3. Mount the jumper, as shown on the picture below: 4. Gently push the electronic board back into the encapsulation again. In any case DO NOT USE FORCE. If difficulty is experienced it is because the light-pipes on the opposite endplate has moved a bit when the electronic board was removed and it might be necessary to loosen the front endplate a bit to make them fit in the holes again. 5. Mount the endplate and secure it with the screws.