Owner`s manual

En g l i s h
Fr a n ç a i s
20
CALIFORNIA COOPERAGE
EQUIPMENT SAFETY FEATURES
Automatic Time Outs
Your California Cooperage® Series Spa is
equipped with an automatic Time Out feature
designed to protect both the equipment and
the user. To reduce unnecessary use of the
pumps and lights, the Time Out feature turns
selected accessories o automatically, as
follows:
Accessory Mode Shuts o in...
Pump 1 Low 4 hours
Pump 1 High 15 minutes
Pump 2 High 15 minutes
Light 4 hours
Blower 15 minutes
If the LCD
displays...
HH
OH
Indicates...
Overheat - one
of the sensors
has detected
water tempera-
ture of 118°F+
(48°C+) inside
the heater
Overheat - One
sensor has de-
tected tempera-
ture of spa water
entering heater
to be 110°F+
(43°C+)
What happens...
Spa heater will
automatically
shut down until
temperature falls
below 108°F
(42°C)
Spa heater will
automatically
shut down until
temperature falls
below 108°F
(42°C)
Possible cause...
- Low speed pump
operating for an extended
period of time
- Programming error
causing continuous
ltering
- Faulty pump
- Low speed pump
operating for an
extended period of time
- Programming error
causing continuous
ltering
- Foulty pump
Corrective Action...
- Make sure slice valves are
open - Reprogram to ensure
time cycles not overlapping
- Contact dealer if problem
persists
- Make sure slice valves are
open - Reprogram to ensure
time cycles not overlapping
- Contact dealer if problem
persists
Common Messages LCD Equipment Safety
The following table describes the most common messages, possible causes, and corrective
actions you may need to take: