Guidebook SmartRead® Plus Automatic Wrist Digital Blood Pressure Monitor with Memory Model 04-248-001 Please read this guidebook completely before operating this unit.
Lifetime Limited Warranty MABIS Healthcare Inc. (“MABIS”) guarantees that its MABIS Digital Blood Pressure Monitor will be free from manufacturing defects under normal use for as long as the original purchaser owns the product. This warranty covers only normal use, and does not apply to use in any clinical or commercial applications. This warranty does not cover batteries or other power sources that may be provided with or used with the MABIS Digital Blood Pressure Monitor.
Introduction To achieve the maximum benefit from your blood pressure monitor, we recommend that you first consult with your physician or trained health care professional. Product Identification & Caution MEMO button LCD Display Thank you for purchasing a MABIS Automatic Wrist Blood Pressure Monitor. With proper care and use, your monitor will provide you with many years of reliable readings.
General Blood Pressure Information What is Blood Pressure? Blood pressure is the pressure that is exerted by blood flowing against the walls of the blood vessels throughout your body. Your heart, which is the center of the circulatory system, provides the force for the blood to flow or circulate. When your heart contracts or beats, the blood is forced through the blood vessels increasing the pressure. This is the highest pressure in the cycle or what is referred to as SYSTOLIC BLOOD PRESSURE.
WHO Blood Pressure Classifications Important Information Before Use Standards for assessment of high or low blood pressure, regardless of age, have been established by the World Health Organization (WHO) as shown in the following chart. 1. Blood pressure measurements should only be interpreted by a physician or a trained health care professional who is familiar with your medical history.
Battery Installation/Replacement Setting the Date/Time The three buttons positioned above the POWER and START buttons are for setting the date and time, Fig. A. 1. Slide battery cover off. Fig.1. button – Sets the entry and/or moves to the next mode. 2. Making sure the battery polarity is correct, install the lower battery. Fig. 1 3. Next, install the upper battery. Fig. 2.. Fig. 2 MEMO button – Increases to the desired value. Fig. A RCAL button – Decreases to the desired value.
Setting the Date/Time Setting the Date/Time To change the date: 7. With the date mode flashing, press the MEMO button or the RCAL button until the desired date appears, Fig. 5. 1 8. Press the Fig. 5 Fig. 2A Fig. 2B 2. Press and hold the button for approximately 3-5 seconds until the date/time disappear (the screen will change twice), Figs. 2A & 2B. Release the button. 4. Press the To change the hour: 9.
Applying Your Blood Pressure Cuff Avoid smoking, eating, taking medication, alcohol consumption or physical activity 30 minutes prior to taking a reading. If you are exhibiting signs of stress, avoid taking your measurement until the feeling subsides. Taking Your Blood Pressure Reading Proceed only after reading the previous sections of this manual. Rest 15 minutes prior to taking a reading. Fig. 1 1. Remove any constrictive clothing or jewelry that may interfere with the cuff placement. 2.
Taking Your Blood Pressure Reading Storing Measurements in Memory 8. The unit will begin to automatically deflate and make “clicking” sounds. Your MABIS Automatic Wrist Monitor can store up to 60 total measurements into two separate memory banks (30 each) these include the date and time of each measurement. The memory feature must be done immediately following reading — prior to turning the unit off. 9. The numbers appearing on the display will decrease, Fig. 5. 10.
Recalling Measurements in Memory You can recall up to 60 total measurements (30 per memory bank) to record on a Blood Pressure Log or to share with your physician or trained health care professional. 1 1. Press the POWER button to turn the unit on. Wait for the display, Fig. 1. Fig. 1 2. Press the button to alternate between memory bank 1 or 2. 3. When the correct memory bank is displayed, press the RCAL button to display your last stored measurement, Fig. 2. 2 4.
Troubleshooting If any abnormality occurs during use, please check and correct the following: Care, Maintenance and Storage 1. Only use a soft, dry cloth to clean your blood pressure monitor. 2. Avoid using any types of liquids on the monitor or cuff. Condition Correction Display is blank when power is on. Check and correct the polarity of the installed batteries. Reinstall or replace batteries. Measurement incomplete or abnormally low or high values displayed.
Product Specifications Name and model number SmartRead® Plus Wrist-styled Blood Pressure Monitor with Memory, 04-248-001 Display system Digital display system/LCD Measuring method Oscillometric method Power source Measuring range Two AAA alkaline batteries Pressure: 20-280 mmHg Pulse: 40-180 beats/minute Pressure: ±3mm Hg Pulse: within ±5% of reading Accuracy Pressurization Deflation Memory Automatic Power Off Sample Blood Pressure Log Automatic pressurization by pump.
Blood Pressure Log Mode d’Emploi SmartRead® Plus de type bracelet Tensiomètre numérique avec mémoire Modèle 04-248-001 Veuillez lire ce mode d’emploi au complet avant de faire fonctionner l’appareil.