Operation
Each unit must be set to the correct MIDI mode, from a choice of Multi,
Master or PCPort on the MIDI mode screen in the Utilities menu. The MIDI
mode setting for each device will depend on the protocol used and whether
synchronization between the units is required.
Note that all units connected via MIDI port will only be synchronized after a
MIDI dump has been performed. Units connected via RS232 do not require
a MIDI dump in order to synchronize, but if a MIDI dump is not performed,
each unit will contain different stored programs and current program settings
until changes are made to each setting individually on the Tx unit).
The default position for the MIDI dump screen is MIDI DUMP: NO. Use the
Parameter UP/DOWN keys to select YES on the Tx unit, then press STORE
at the prompt, to confirm the dump. A percentage complete figure on the Tx
screen will show how much data has been transferred. The Rx screen will
read Warning! Incoming Dump. When the dump is complete, the Tx screen
will default to NO. The Rx screen will display the name of the new current
program.
Notes that all parameter edits in all stored programs will be overwritten in
any CUSTOMER UNIT set to the same MIDI channel. Use MIDI Dump with
care!)
Delete program
This facility allows any stored program to be removed from the unit. Use the
Parameter UP/DOWN keys to select the desired program, and press
STORE to confirm deletion.
Note that programs marked M cannot be deleted from USER units.
Protocol Tx Rx Sync. Status
RS232 PCPort Multi -
RS232 PCPort PCPort -
RS232 Multi Multi -
RS232 Multi PCPort -
RS232 Master Multi Synchronized
RS232 Master PCPort Synchronized
MIDI Multi Master -
MIDI Master Master Synchronized after
dump.