User Manual

200 BENCH PROCEDURES
Page 5-63
Econovance Disassembly
Refer to Figure 5-75.
1. Place scalloped drive hub (5) in a vise
equipped with brass jaws. Remove drive-
hub retaining capscrew (10) and washer (9)
while holding inner shaft assembly (2) at
rear of Econovance. This will prevent
assembly from dropping out of housing
when retaining capscrew is removed.
2. Using snap-ring pliers, remove snap ring (1)
from rear of Econovance housing (8).
3. Remove inner shaft assembly from rear of
Econovance housing by manually guiding
gear assembly outward.
4. Remove inner sleeve (4) from inner shaft
assembly.
5. Remove and inspect Econovance spring (3)
for cracks or signs of wear.
6. Remove outer shaft drive hub (5) from
housing (8).
Figure 5-75 Econovance Assembly
1. Retainer ring
2. Inner shaft assembly
3. Econovance spring
4. Inner sleeve
5. Outer shaft drive hub
6. Solenoid valve
7. Valve housing
8. Econovance housing
9. Washer
10. Drive hub retaining capscrew
5-101.bk Page 63 Friday, March 17, 2006 11:05 AM