200 ENGINE ASSEMBLY
[215 SW] WATER PUMP
Installation
Refer to Figure 6-92.
Water pump-to-housing mounting capscrews
should not be lubricated before installation.
Instead, apply thread sealing compound to all
water pump-to-water pump housing capscrews.
Also apply thread sealing compound to water
pump housing (pump outlet) to block capscrews.
1. Position a gasket on the water pump
mounting flange.
2. Secure pump with three mounting
capscrews (3).
3. Position refrigerant compressor support
bracket, if required, on the front of the
cylinder head. (Insert spacer if refrigerant
compressor support bracket and fan ring
arrangement are not used.) Secure bracket
with mounting hardware.
Figure 6-92 Water Pump Installation
1. Air compressor line
2. Water pump
3. Capscrew
200358a
1
2
3
3
3
5-101.bk Page 76 Friday, March 17, 2006 11:05 AM