User`s manual

12
7
Disable
Enable
Play Next
Enabling Play Next allows Start 8 input
(Connector 1, Pos. 9) to initiate playback of the
next valid message sequence. The first start
activation after power on will play message 1. All
operation modes are supported and other start
inputs (1 - 7) are disabled.
8
Disable
Memory Protect
Allows the user to lock message memory so that
messages may not be accidentally overwritten. Enable
2.2.3. Connector 1
12 position pluggable terminal strip. Use for remote activation of
message playback, stopping messages, and playing relay
output. Activation can be made through mechanical contact or
open collector driver. 3mA activation current.
1 Common ground for all inputs
2 Start 1 Input, connect to common for message 1 playback
3 Start 2 Input, connect to common for message 2 playback
4 Start 3 Input, connect to common for message 3 playback
5 Start 4 Input, connect to common for message 4 playback
6 Start 5 Input, connect to common for message 5 playback
7 Start 6 Input, connect to common for message 6 playback
8 Start 7 Input, connect to common for message 7 playback
9 Start 8 Input, connect to common for message 8 playback
10 Stop Input, connect to common to stop message playback or
recording
11 Play Relay Output, Common
12 Play Relay Output, Form A, connects to position 11 when
playing.