Service manual
Table Of Contents
- SPARC Enterprise M4000/M5000 Servers
- Contents
- Preface
- Safety and Tools
- Fault Isolation
- 2.1 Determining Which Diagnostics Tools to Use
- 2.2 Checking the Server and System Configuration
- 2.3 Operator Panel
- 2.4 Error Conditions
- 2.5 LED Functions
- 2.6 Using the Diagnostic Commands
- 2.7 Traditional Oracle Solaris Diagnostic Commands
- 2.8 Other Issues
- Periodic Maintenance
- FRU Replacement Preparation
- Internal Components Access
- Storage Devices Replacement
- 6.1 Hard Disk Drive Replacement
- 6.1.1 Accessing the Hard Disk Drive
- 6.1.2 Removing the Hard Disk Drive
- 6.1.3 Installing the Hard Disk Drive
- 6.1.4 Securing the Server
- 6.1.5 Accessing the Hard Disk Drive Backplane of the M4000 Server
- 6.1.6 Removing the Hard Disk Drive Backplane of the M4000 Server
- 6.1.7 Installing the Hard Disk Drive Backplane of the M4000 Server
- 6.1.8 Securing the Server
- 6.1.9 Accessing the Hard Disk Drive Backplane of the M5000 Server
- 6.1.10 Removing the Hard Disk Drive Backplane of the M5000 Server
- 6.1.11 Installing the Hard Disk Drive Backplane of the M5000 Server
- 6.1.12 Securing the Server
- 6.2 CD-RW/DVD-RW Drive Unit (DVDU) Replacement
- 6.2.1 Identifying the Type of CD-RW/DVD-RW Drive Unit
- 6.2.2 Accessing the CD-RW/DVD-RW Drive Unit
- 6.2.3 Removing the CD-RW/DVD-RW Drive Unit
- 6.2.4 Installing the CD-RW/DVD-RW Drive Unit
- 6.2.5 Securing the Server
- 6.2.6 Accessing the CD-RW/DVD-RW Drive Backplane of the M4000 Server
- 6.2.7 Removing the CD-RW/DVD-RW Drive Backplane of the M4000 Server
- 6.2.8 Installing the CD-RW/DVD-RW Drive Backplane of the M4000 Server
- 6.2.9 Securing the Server
- 6.2.10 Accessing the CD-RW/DVD-RW Drive Backplane of the M5000 Server
- 6.2.11 Removing the CD-RW/DVD-RW Drive Backplane of the M5000 Server
- 6.2.12 Installing the CD-RW/DVD-RW Drive Backplane of the M5000 Server
- 6.2.13 Securing the Server
- 6.3 Tape Drive Unit Replacement
- 6.3.1 Accessing the Tape Drive Unit
- 6.3.2 Removing the Tape Drive Unit
- 6.3.3 Installing the Tape Drive Unit
- 6.3.4 Securing the Server
- 6.3.5 Accessing the Tape Drive Backplane of the M4000 Server
- 6.3.6 Removing the Tape Drive Backplane of the M4000 Server
- 6.3.7 Installing the Tape Drive Backplane of the M4000 Server
- 6.3.8 Securing the Server
- 6.3.9 Accessing the Tape Drive Backplane of the M5000 Server
- 6.3.10 Removing the Tape Drive Backplane of the M5000 Server
- 6.3.11 Installing the Tape Drive Backplane of the M5000 Server
- 6.3.12 Securing the Server
- 6.1 Hard Disk Drive Replacement
- Power Systems Replacement
- I/O Unit Replacement
- 8.1 PCI Cassette Replacement
- 8.2 PCI Card Replacement
- 8.3 I/O Unit Replacement
- 8.4 I/O Unit DC-DC Converter Replacement
- 8.4.1 Accessing the I/O Unit DC-DC Converter (DDC_A#0 or DDC_B#0)
- 8.4.2 Removing the I/O Unit DC-DC Converter (DDC_A #0 or DDC_B #0)
- 8.4.3 Installing the I/O Unit DC-DC Converter (DDC_A #0 or DDC_B #0)
- 8.4.4 Securing the Server
- 8.4.5 Accessing the I/O Unit DC-DC Converter Riser
- 8.4.6 Removing the I/O Unit DC-DC Converter Riser
- 8.4.7 Replacing the I/O Unit DC-DC Converter Riser
- 8.4.8 Securing the Server
- XSCF Unit Replacement
- Fan Modules Replacement
- 10.1 Fan Module Replacement
- 10.1.1 Accessing the 60-mm Fan Module
- 10.1.2 Removing the 60-mm Fan Module
- 10.1.3 Installing the 60-mm Fan Module
- 10.1.4 Securing the Server
- 10.1.5 Accessing the 172-mm Fan Module
- 10.1.6 Removing the 172-mm Fan Module
- 10.1.7 Installing the 172-mm Fan Module
- 10.1.8 Securing the Server
- 10.1.9 Accessing the 60-mm Fan Backplane
- 10.1.10 Removing the 60-mm Fan Backplane
- 10.1.11 Installing the 60-mm Fan Backplane
- 10.1.12 Securing the Server
- 10.1.13 Accessing the SPARC Enterprise M4000 172-mm Fan Backplane
- 10.1.14 Removing the SPARC Enterprise M4000 172-mm Fan Backplane
- 10.1.15 Installing the M4000 Server 172-mm Fan Backplane
- 10.1.16 Securing the Server
- 10.1.17 Accessing the M5000 Server 172-mm Fan Backplane
- 10.1.18 Removing the M5000 Server 172-mm Fan Backplane
- 10.1.19 Installing the M5000 Server 172-mm Fan Backplane
- 10.1.20 Securing the Server
- 10.1 Fan Module Replacement
- Memory Board Replacement
- CPU Module Replacement
- 12.1 CPU Module Replacement
- 12.2 CPU Upgrade
- 12.2.1 SPARC64 VII/SPARC64 VII+ CPU Modules Added to a New Domain
- 12.2.2 SPARC64 VII/SPARC64 VII+ Processors Added to an Existing Domain
- Adding a SPARC64 VII/SPARC64 VII+ CPU Module to a Domain Configured With SPARC64 VI
- 12.2.3 Upgrading a SPARC64 VI CPU Module to SPARC64 VII/SPARC64 VII+ on an Existing Domain
- Motherboard Unit Replacement
- 13.1 Motherboard Unit Replacement
- 13.1.1 Accessing the M4000 Server Motherboard Unit
- 13.1.2 Removing the M4000 Server Motherboard Unit
- 13.1.3 Installing the M4000 Server Motherboard Unit
- 13.1.4 Securing the Server
- 13.1.5 Accessing the M5000 Server Motherboard Unit
- 13.1.6 Removing the M5000 Server Motherboard Unit
- 13.1.7 Installing the M5000 Server Motherboard Unit
- 13.1.8 Securing the Server
- 13.2 DC-DC Converter Replacement
- 13.2.1 Accessing the M4000 Server DC-DC Converter
- 13.2.2 Removing the M4000 Server DC-DC Converter
- 13.2.3 Installing the M4000 Server DC-DC Converter
- 13.2.4 Securing the Server
- 13.2.5 Accessing the M5000 Server DC-DC Converter
- 13.2.6 Removing the M5000 Server DC-DC Converter
- 13.2.7 Installing the M5000 Server DC-DC Converter
- 13.2.8 Securing the Server
- 13.3 Motherboard Unit Upgrade
- 13.1 Motherboard Unit Replacement
- Backplane Unit Replacement
- 14.1 Backplane Unit Replacement
- 14.1.1 Accessing the M4000 Server Backplane Unit
- 14.1.2 Removing the M4000 Server Backplane Unit
- 14.1.3 Installing the M4000 Server Backplane Unit
- 14.1.4 Securing the Server
- 14.1.5 Accessing the M5000 Server Backplane Unit
- 14.1.6 Removing the M5000 Server Backplane Unit
- 14.1.7 Installing the M5000 Server Backplane Unit
- 14.1.8 Securing the Server
- 14.1 Backplane Unit Replacement
- Operator Panel Replacement
- Components List
- Rules for System Configuration
- FRU List
- External Interface Specifications
- UPS Controller
- Air Filters
- Abbreviations
- Index

Chapter 8 I/O Unit Replacement 8-7
Note – When you insert the PCI cassette using hot-swap, the cassette is
automatically powered on and configured. Check that the POWER LED on the
cassette is lit to be certain the cassette is correctly seated.
3. Connect all cables to the PCI cassette and reconnect the cable management arm
if necessary.
8.1.4 Securing the Server
1. Add the PCI cassette to the system.
This step includes using the cfgadm command to connect and confirm the PCI
cassette has been added to the system. See Section 4.2.3, “Adding a FRU Into a
Domain” on page 4-5.
2. Verify the state of the status LEDs on the PCI cassette.
The green POWER LED should be On and the CHECK LED should not be On.
8.2 PCI Card Replacement
The PCI card mounts in the PCI cassette.
8.2.1 Removing the PCI Card
1. Remove the PCI cassette containing the PCI card from the server.
See Section 8.1.2, “Removing the PCI Cassette” on page 8-5.
2. Open the cassette lever until it is horizontal (
FIGURE 8-5).
3. Loosen the three (3) captive screws on the adjustable stops with a screwdriver
and move the adjustable stops away from the PCI card.
4. Remove the PCI card from the cassette and place it on the ESD mat.