Brochure
Table Of Contents
Phone (413) 594-8695 · Fax (413) 598-8109
www.tunstall-inc.com • www.maconcontrols.com
Bulletin-MC-RCM-1014
Electric Operators
Tunstall Corporation
118 Exchange Street • Chicopee, MA 01013
© July 2014
We reserve the right to alter designs, specifications and information without notice.
Remote Control Module -
MAC-RCM
13
Set setpoint for comfort mode and reduced temperature mode
► Press the knob for 2 s.
► Select the “Setpoint” function using the knob.
► Press the knob.
The setpoint for comfort mode flashes and can now be set.
► Confirm the chosen setpoint for comfort mode by pressing the knob.
► The setpoint for reduced temperature mode flashes and can now be set.
► Confirm the chosen setpoint for reduced temperature mode by pressing the knob.
Setting the time and date
► Press the knob for 2 s.
► Use the knob to select the “Time + Date” function TIME and press the knob.
The hour, minutes, year, month and day can then be set in sequence.
► Set the time:
Set the hour. Confirm setting by pressing the knob.
Set the minutes. Confirm setting by pressing the knob.
► Set the year:
Confirm setting by pressing the knob.
► Set the month and day:
Set the month. Confirm setting by pressing the knob.
Set the day. Confirm setting by pressing the knob.
■ The switch to daylight saving time occurs automatically according to Central Europeans stan-
dards.
Setting 24/12 hour display
► Press the knob for 2 s.
► Use the knob to select the “24/12 hour display” function 24h and press the knob.
► Set 24 or 12 hour display.
Confirm setting by pressing the knob.
■ If the 12 hour display is activated, an additional A for AM
or P for PM is shown in the display.
Switching the temperature units °C/°F
► Press the knob for 2 s.
► Use the knob to select the “Set the temperature units °C/°F” function TEMP and press the
knob.