13 
Set setpoint for comfort mode and reduced temperature mode 
► Press the knob for 2 s. 
► Select the “Setpoint” function using the knob. 
► Press the knob. 
The setpoint for comfort mode flashes and can now be set. 
► Confirm the chosen setpoint for comfort mode by pressing the knob. 
► The setpoint for reduced temperature mode flashes and can now be set. 
► Confirm the chosen setpoint for reduced temperature mode by pressing the knob. 
Setting the time and date 
► Press the knob for 2 s. 
► Use the knob to select the “Time + Date” function TIME and press the knob. 
The hour, minutes, year, month and day can then be set in sequence. 
► Set the time: 
Set the hour. Confirm setting by pressing the knob. 
Set the minutes. Confirm setting by pressing the knob. 
► Set the year: 
Confirm setting by pressing the knob. 
► Set the month and day: 
Set the month. Confirm setting by pressing the knob. 
Set the day. Confirm setting by pressing the knob. 
■ The switch to daylight saving time occurs automatically according to Central Europeans stan- 
dards. 
Setting 24/12 hour display 
► Press the knob for 2 s. 
► Use the knob to select the “24/12 hour display” function 24h and press the knob. 
► Set 24 or 12 hour display. 
Confirm setting by pressing the knob. 
■ If the 12 hour display is activated, an additional A for AM 
or P for PM is shown in the display. 
Switching the temperature units °C/°F 
► Press the knob for 2 s. 
► Use the knob to select the “Set the temperature units °C/°F” function TEMP and press the 
knob. 