Warranty & Engineering Data 
Macon Controls
Straight valve with straight nipple. 
NPT - female inlet, male union outlet. 
1/2” - N10737 
3/4” - N10757 
1” - N10777 
1-1/4” - N10797 
Vertical angle valve with straight nipple. 
NPT - female inlet, male union outlet. 
1/2” - N10637 
3/4” - N10657 
1” - N10677 
1-1/4” - N10697 
Horizontal angle valve with straight nipple. 
NPT - female inlet, male union outlet. 
1/2” - N10837 
3/4” - N10857 
1” - N10877 
1-1/4” - N10897 
Sweat valve with female inlet and outlet. 
1/2” - N10930 
3/4” - N10950 
1” - N10970 
EDV - Designed for mixing or diverting flows in 
various water based heat or cooling transmission 
systems, such as radiator loops, floor heating, etc. 
Add appropriate operator. 
OPSK - Consists of the reliable MTW direct 
mounting thermostat. It controls room temperature 
by regulating the amount of air and steam in the 
radiator. 
MTW - Non-Electric direct mounting thermostat 
with a numerical window reading that corresponds 
to various temperatures. May be limited or locked 
if required. Features heat diffusing rings to dissi-
pate heat away from sensor for added accuracy. 
MTWZ - Non-Electric, fully automatic thermostat 
with valve mounted temperature setting dial and 
remote sensor. 
ENTL B46000 - Non-Electric, fully automatic 
remote thermostat with built-in remote sensor and 
temperature setting dial. 
ENTLZ B56000 - Non-Electric, fully automatic 
thermostat with separate remote sensor and remote 
temperature setting dial. 
VMC (normally closed) & VMO (normally open) - 
24-Volt controller designed for use with the Macon 
NT series valves. Ideal for control of radiators, fin-
tube, zones, fan coils, heat pumps, radiant floor, 
etc... 
VM 2-10V is used to regulate valves in heating 
and cooling systems using a built-in processor. 
ZMC ES (End Switch - normally closed) is con-
trolled by a 24V room thermostat with two-point 
output or pulse-width modulation. 
ZMC-DDC (Proportional - normally closed) is 
used to regulate valves via a central DDC system 
or by a room thermostat. 
MVA 2-10V - Motorized Electric zone control 
actuator for controllers with continuous output in 
conjunction with single-room control systems. 