Operation Instructions
Table Of Contents
- 1 General Safety Information
- 2 Use Instructions and Limitations
- 3 Installation Instructions
- 3.1 Location & Mounting
- 3.2 Installation
- 3.2.1 General Wiring Information
- 3.2.2 Installation Diagram
- 3.2.3 Power Connection
- 3.2.4 Remote Sensor Connection
- 3.2.4.1 MRS-485 Connection and Operation
- 3.2.4.2 Connection
- 3.2.4.3 Dip Switches and Addressing
- 3.2.4.4 Topology
- 3.2.4.5 Line Termination – End of Line Resistor
- 3.2.4.6 Baud Rate
- 3.2.4.7 Wire Selection
- 3.2.4.8 Wire Length
- 3.2.4.9 Grounding
- 3.2.4.10 External Power Supply
- 3.2.4.11 Power Wire
- 3.2.4.12 4-20mA Connection
- 3.2.4.13 Relay Connection
- 3.2.5 Remote Relay Connection
- 3.2.6 Remote Relay Operation
- 3.2.7 Horn & Strobe Connection
- Figure 3-4 – System Wiring Diagram
- 4 Operations
- 4.1 Power up
- 4.2 User Interface
- 4.3 Normal Status Display
- 4.4 ALARM, WARNING, and TROUBLE Status Display
- 4.5 Ventilation Control
- 4.6 Main Menu
- Figure 4-6 –
- 4.6.1 CONFIGURE SYSTEM?
- 4.6.2 MANUAL CONFIGURE?
- 4.6.3 CONFIGURE RELAYS, H/S, BUZZER?
- 4.6.4 COMMUNICATION?
- 4.6.5 VIEW SENSORS?
- 4.6.6 DATE/TIME – PASSWORD?
- 4.6.7 EVENTS?
- 4.6.8 TECHNICAL SUPPORT?
- 5 BACnet
- 5.1 General Information
- Table 5-1 – Types of Detector
- Table 5-2 – Engineering Unit
- Table 5-3 – BACnet Objects for Group Settings of all Zone
- Table 5-4 – BACnet Object for Detector Reading
- Table 5-5 – Bit Assignment for Zone[N]. mode value
- Table 5-6 – BACnet Objects for Zone Configuration
- Table 5-7 – BACnet Objects for DVP-1200 Outputs
- 5.1 General Information
- 6 Testing & Maintenance
- 7 Appendix A – Table of Figures
- 8 Appendix C – Replacement Parts
- 9 Appendix D – Setup Record
- 10 Macurco Gas Detection Product limited warranty
- Blank Page
- Blank Page
- Blank Page
Macurco
TM
DVP-1200 Manual
REV – 1.3.1 [34-8708-4770-7 ] 53 | Page
Description
BACnet Object Type
BACnet Object Instance
Zone[N]
N is from
1 to 8
Gas
sensor
[CO]
type
Analog value
0+(N-1)*68
Eng. unit
Analog value
1+(N-1)*68
range
Analog value
2+(N-1)*68
Alarm
Analog value
3+(N-1)*68
Warning
Analog value
4+(N-1)*68
Rising
Analog value
5+(N-1)*68
Falling
Analog value
6+(N-1)*68
Gas
sensor
[NO
2
]
type
Analog value
7+(N-1)*68
Eng. unit
Analog value
8+(N-1)*68
range
Analog value
9+(N-1)*68
Alarm
Analog value
10+(N-1)*68
Warning
Analog value
11+(N-1)*68
Rising
Analog value
12+(N-1)*68
Falling
Analog value
13+(N-1)*68
Gas
sensor
[EX]
type
Analog value
14+(N-1)*68
Eng. unit
Analog value
15+(N-1)*68
range
Analog value
16+(N-1)*68
Alarm
Analog value
17+(N-1)*68
Warning
Analog value
18+(N-1)*68
Rising
Analog value
19+(N-1)*68
Falling
Analog value
20+(N-1)*68
Gas
sensor
[NH
3
]
type
Analog value
21+(N-1)*68
Eng. unit
Analog value
22+(N-1)*68
range
Analog value
23+(N-1)*68
Alarm
Analog value
24+(N-1)*68
Warning
Analog value
25+(N-1)*68
Rising
Analog value
26+(N-1)*68
Falling
Analog value
27+(N-1)*68
Gas
sensor
[H
2
S]
type
Analog value
28+(N-1)*68
Eng. unit
Analog value
29+(N-1)*68
range
Analog value
30+(N-1)*68
Alarm
Analog value
31+(N-1)*68
Warning
Analog value
32+(N-1)*68
Rising
Analog value
33+(N-1)*68
Falling
Analog value
34+(N-1)*68
Gas
sensor
[REF]
type
Analog value
35+(N-1)*68
Eng. unit
Analog value
36+(N-1)*68
range
Analog value
37+(N-1)*68
Alarm
Analog value
38+(N-1)*68
Warning
Analog value
39+(N-1)*68
Rising
Analog value
40+(N-1)*68
Falling
Analog value
41+(N-1)*68
Gas
sensor
[O
2
]
type
Analog value
49+(N-1)*68
Eng. unit
Analog value
50+(N-1)*68
range
Analog value
51+(N-1)*68
Alarm
Analog value
52+(N-1)*68
Warning
Analog value
53+(N-1)*68