G
ENERAL SAFETY INFORMATION
I
NTENDED USE
T
he GD-2A is a low voltage (12-24 VAC or VDC) electronic detector of
c
ombustible, heating type gases. The GD-2A is designed for connection to
U
L Listed Fire Alarm/Burglary Control Panels. NOTE: Any time the words
“
Control Panel” or “Alarm Panel” or “Alarm Control Panel” are used in these
i
nstructions, they refer to a UL Listed Fire Alarm/Burglary Control Panel.
A
larm control panels that work on 12 or 24 VDC can provide battery backup
t
o the GD-2A detectors. This combustible gas detector has been evaluated
b
y UL for methane (natural gas) and propane (LP) gas. It is NOT designed
t
o detect smoke, fire or carbon monoxide.
L
IST OF WARNINGS AND CAUTIONS
•
Each person using this equipment must read and understand the
i
nformation in these User Instructions before use. Use of this equipment by
u
ntrained or unqualified persons, or use that is not in accordance with these
U
ser Instructions, may adversely affect product performance and result in
s
ickness or death.
•
Use only for monitoring the gas which the sensor and detector are
d
esigned to monitor. Failure to do so may result in exposures to gases not
detectable and cause sickness or death. For proper use, see supervisor
or User Instructions, or call Macurco Technical Service.
• GD-2A may not function effectively below 32 °F or above 120°F. Using
the detector outside of this temperature range may adversely affect product
performance and result in sickness or death.
• This detector helps monitor for the presence and concentration level of
certain specified airborne gases. Misuse may produce an inaccurate
reading,
which means that higher levels of the gas being monitored may be
present and could result in overexposure and cause sickness or death.
For proper use, see supervisor or User Instructions, or call Macurco
Technical Service.
• The GD-2A is not designed to measure compliance with Occupational
Safety and Health Administration (OSHA) commercial or industrial
standards.
• When the unit is powered up i
t performs a self-test during which the green
LED light will blink for a period of one and one half to two minutes.
Afterward, the green LED light will turn on continuously to indicate the unit is
in normal operation (ARMED). If the self-test fails or the green LED light
does not turn on continuously do not use. Failure to do so may adversely
affect product performance and result in sickness or
death.
• Immediately exit the environment if there is an alarm condition on the
detector. Failure to do so may result in sickness or death.
• This detector will only indicate the presence of combustible gas at the
sensor. Combustible gas may be present in other areas. Accommodation
spaces should be well ventilated when household cleaning supplies or
similar contaminants are used.
• Do not cover or
obstruct visual alarm LED. Doing so may adversely affect
product performance and result in sickness or death.
• Do not disassemble unit or attempt to repair or modify any component of
this detector. This detector contains no user serviceable parts, and
substitution of components may adversely affect product performance and
result in sickness or death.
CAUTION
• Avoid the use of harsh cleaning
materials, abrasives and other organic
solvents. Such materials may permanently scratch the surfaces; damage
the sensor, labels, or instrument housing.
• If you have any doubts about the applicability of the equipment to your job
situation, consult an industrial hygienist or call Macurco Technical Service.
USE INSTRUCTIONS AND LIMITATIONS
Each person using this equipment must read and understand the information in
these User Instructions before use. Use of this equipment by untrained or
unqualified persons, or use that is not in accordance with these User Instructions,
may adversely affect product performance and result in sickness or death.
USE FOR
The GD-2A is an electronic detector of combustible, heating type gases
(natural gas and propane), designed for connection to alarm control
panels.
It can operate on 12 to 24 VDC power from standby or interruptible panel
power, or be powered separately. The GD-2A is intended for installation in
buildings in non-hazardous locations such as residences, retail stores, office
buildings, and institutional buildings.
Use only for monitoring the gas which the sensor and detector are designed to
monitor. Failure to do so may result in exposures to gases not detectable and cause
sickness or death. For proper use, see supervisor or User Instructions, or call
Macurco Technical Service.
DO NOT USE FOR
The GD-2A is NOT intended for use in industrial applications such as
ref
ineries, chemical plants, etc. The GD-2A does NOT detect carbon
monoxide. Do NOT mount the GD-2A in a corner. The GD-2A is designed
for connection to UL Listed Fire Alarm/Burglary Control Panels. Do not
connect the GD-2A to Fire Alarm Circuits, or Burglar Alarm or other signals.
The Alarm Control Panel must be dedicated to gas detection or have alarm
devices that provide a distinctive alarm for ga
s detection. Do NOT mount
the GD-2A in kitchens or bathrooms - alcohol’s, ammonia, cleaning solvents,
paint thinner, gasoline vapors, and aerosol propellants (aerosol cans such
as hair spray usually contain a combustible gas) may cause nuisance
alarms.
GD-2A may not function effectively below 32 °F or above 120°F. Using the detector
outside of this temperature range may adversely affect produc
t performance and
result in sickness or death.
GENERAL DESCRIPTION
The GD-2A is a low voltage (12-24 VAC or VDC) electronic detector of
combustible, heating type gases, that has been evaluated by UL for
methane (natural gas) and propane (LP) gas. The GD-2A is designed for
connection to UL Listed Fire Alarm/Burglary Control Panels. The GD-2A has
a SPDT Alarm relay, for connection to control panels
or other devices. The
GD-2A does NOT detect carbon monoxide. The GD-2A does not have an
internal audible sounder.
FEATURES
• LISTED TO UL STANDARD 2075 FOR THE STANDARD FOR SAFETY FOR
GAS AND VAPOR DETECTOR AND SENSORS
• SENSITIVITY TESTED BASED ON UL 1484 STANDARD FOR RESIDENTIAL
GAS DETECTORS
• DETECTS HEATING GASES: PROPANE (LP), NATURAL GAS (METHANE),
• SPDT ALARM AND N.C. TROUBLE RELAYS
• CA
N BE SELF-RESTORING OR LATCHING
• ELECTRONIC SENSORS: NO MAINTENANCE OR RECALIBRATION
• TEMPERATURE COMPENSATED
• SIMPLE INSTALLATION AND OPERATION
• SUPERVISED SENSOR
SPECIFICATIONS
• SIZE: 4 ½ X 5 X 1 5/8 inches
• SHIPPING WEIGHT: 0.54 pound
• VOLTAGE: 12 to 24 VAC or VDC
• CURRENT (non-alarm): 45 mA @ 12 VDC, 22 mA @ 24 VDC, 65 mA @ 12 VAC,
45 mA @ 24 VAC
• CURRENT (in alarm): 70 mA @ 12 VDC, 35 mA @ 24 VDC, 100 mA @ 12 VAC
,
65 mA @ 24 VAC
• COLOR: White
• SENSOR MAINTENANCE: Not required
• ALARM RELAY RATING: 0.125 AMPS, 40V, 3VA
• TROUBLE RELAY: 0.250 AMPS, 40V, 10VA
• OPERATING TEMPERATURE RANGE: 32° to 120° F
• ALARM SET POINT: Per UL 1484 (25% LEL)
INSTALLATION AND OPERATING INSTRUCTIONS
The following instructions are intended to serve as a guideline for the use o
f
the Macurco GD-2A Combustible Gas Detector. It is not to be considere
d
all-inclusive, nor is it intended to replace the policy and procedures for eac
h
facility.
This detector helps monitor for the presence and concentration level of certai
n
specified airborne gases. Misuse may produce an inaccurate reading, which mean
s
that higher levels of the gas being monitored may be present and could result i
n
overexposure and cause sickness or death. For proper use, see supervisor o
r
User Instructions, or call Macurco Technical Service.
LOCATION
A GD-2A is usually located in each room (except kitchens or bathrooms
)
where there are gas appliances or through which gas pipes pass. Do NO
T
mount the GD-2A in a corner. Do NOT mount the GD-2A in kitchens o
r
bathrooms - alcohol’s, ammonia, cleaning solvents, paint thinner, gasolin
e
vapors, and aerosol propellants (aerosol cans such as hair spray usuall
y
contain a combustible gas) may cause alarms. Do NOT mount the GD-2
A
where the normal ambient
This product is intended for use in ordinary indoor locations of family livin
g
units and office workspaces.
The GD-2A is not designed to measure compliance with Occupational Safety an
d
Health Administration (OSHA) commercial or industrial standards.
INSTALLATION
1. If the gas used is natural gas (methane) mount the GD-2A on a wall abou
t
one foot down from the ceiling. If the gas used is propane (LP), mount th
e
GD-2A on a wall or column one foot above the floor. Use the same spacin
g
as for smoke detectors- 30-foot centers, 900 square feet per detector.
The three part plastic case allows the GD-2A to be either surface mounted
or installed over a four-inch square or double gang electrical box, providing
a near flush mount. The GD-2A snap on front cover will need to be removed
before installation. To remove it, lightly pry the front cover off of the
mounting plate (middle section) with a coin or flat screwdriver inserted into
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING
! WARNING