Installation Instructions

FI_CE_NG_DETECT_LINE_USB_FCC_V1_00US.docx 3/20
Presentation
DETECT LINE NG: High Voltage line volumeric detector: HVA (< 50 kV) and HVB (> 50 kV).
DETECT LINE NG warns the user by an audible alarm when the lifting machine enters a risk
zone.
Central unit
Sensor management and control sensors, generation of audible and visual alarms, movement blocking
management (optional). Lamp « power on »
System in working order
Electric field present
Breakdown
- Lamp "Audible alarm" off
- Lamp "Movement cut" off
- Lamp "Visual alarm" off.
- Lamp "On work" light on steady.
* slow flash: system
waiting for alarm activation
- Lamp "Audible alarm" flashing*.
- Lamp "Movement cut" light on
steady*
-Lamp "Visual alarm" light on steady
-Lamp "On work" light on steady.
- Buzzer on*.
- Lamp "On work" off: power
off
- slow flash: system waiting
for alarm activation
- flashing fast: equipment
fault.
* Until press "Alarm Report" button located on the display unit.
Outside display unit
The outside display unit indicates the danger and allows acknowledging the audible alarm and the "Movement
cut" (optional).
System in working order
Electric field present
Breakdown
- Lamp "Danger" off
- Lamp "DANGER" flashing*.
- Buzzer on*.
- flashing fast: equipment
fault.
* Until press "Alarm Report" button located on the outside display unit.
Sensor
Sensor measure the electric field radiated by the High Voltage lines and communicates by wire connection
with the CPU.