pHTemp2000 Data Logger Manual Red 485 Dark Blue Pantone 289 Light Blue 58% of Pantone 289
Table of Contents Data Logger Manual Section 1: Device Safety............................................................................3 1.1 Model information....................................................................3 1.2 Specifications............................................................................3 1.3 Warranty...................................................................................5 Section 2: Device Overview...............................................................
MadgeTech pHTemp2000 6.7 Temperature Channel Statistics:...............................................21 6.8 pH Channel Statistics:..............................................................21 6.9 Type Statistics:.........................................................................22 6.10 Statistics Information Screen:.................................................22 6.11 Unit Selection Menu:.............................................................23 6.12 Device Configuration Menu:............
Data Logger Manual Section 1: Device Safety CAUTION: DEVICE MUST BE USED ONLY IN A MANNER CONSISTENT WITH THIS MANUAL. NOTICE: WHEN 230VAC SUPPLY USED, MADGETECH SPECIFIES USE OF AC SUPPLY PART # T35-9-100R-3 MANUFACTURED BY ENG ELECTRIC. THIS SUPPLY IS AVAILABLE FROM MADGETECH. 1.1 Model information • Model: pHTemp2000 • Description: Measure & record pH and temperature using an external probe with LCD display • Manufactured by MadgeTech, Inc. Warner, NH USA 1.
MadgeTech pHTemp2000 Start/Stop Time: Software programmable start time and date, up to six months in advance; programmable stop method, manual, timed, or by readings.
Data Logger Manual 1.3 Warranty Products manufactured by MadgeTech, Inc., are warranted against defective material and workmanship for a period of one year, starting from the date of shipment. In the event that a MadgeTech product is found to be defective, MadgeTech will repair or replace the product at its sole discretion. Such repair or replacement shall be the sole remedy of this warranty.
MadgeTech pHTemp2000 Section 2: Device Overview Power Jack LED Indicators LCD Screen Communication Jack Up Key BNC Connector Black anodized aluminum enclosure Page 6 Okay Key Down Key Function Keys Cancel Key
Data Logger Manual Section 3: Status Indicator Icons 3.1 Battery Status Full Empty Battery Battery Battery status icons indicate the state of charge of the batteries. When the battery empty indicator is displayed, the battery should be replaced. 3.2 Memory Status Memory Empty Memory Full The memory status icons indicate the amount of memory left for data storage. If the pHTemp2000 is in wraparound mode, the memory status icon will always indicate empty. 3.
MadgeTech pHTemp2000 3.4 Delay Start Indicator The delay start icon indicates that a logging operation is scheduled for the future. 3.5 Wait Icon The wait icon indicates that the device is busy. 3.6 Stop Icon Indicates that the pHTemp2000 is not currently taking readings. 3.7 External Power Icon Indicates that the pHTemp2000 is powered by an external source. 3.8 Reset Icon Indicates that the device has been reset.
Data Logger Manual Section 4: Front Panel Overview 4.1 Changing the display units The pHTemp2000 comes with factory default display units of °C for the RTD temperature channel, and pH for the pH channel. These units can be easily changed by pressing the F3 button in the main screen and then selecting either F1 for the RTD temperature or F2 for pH probe.
MadgeTech pHTemp2000 Large: Both channels can be displayed and take up entire available screen space. Button pressing chain: Main Screen -> F4 -> F1 -> F4 -> F2 repeatedly to scroll or UP and DOWN to scroll 4.3 Checking the memory Status A status icon appears on all screens representing memory, but further information including percent memory left and number of readings taken can also be viewed.
Data Logger Manual Section 5: pHTemp2000 Function Reference 5.1 Main Screen The main screen of the pHTemp2000 features a real-time display of most recently measured RTD temperature and pH probe data. At the bottom of the main screen are tabs corresponding to each of the four function keys. These tabs are used to access the four main function menus of the pHTemp2000: status, statistics, units, and setup.
MadgeTech pHTemp2000 5.2.iii Time The time screen displays current time data including the current time and date, time and date of last measured data, and current time zone. 5.3 Statistics Menu Pressing the F2 key while in the Main Screen brings up the Statistics Menu. From the Statistics Menu, statistics generated from the conditions encountered by the device can be viewed in a variety of different styles including being sorted by channel and by type.
Data Logger Manual 5.4 Units Pressing the F3 key while viewing the Main Screen will access the Units Selection screen. Here the measurement units can be easily changed. In the Units Selection screen the F1 and F2 function keys correspond to the two channels RTD temperature and pH probe respectively.
MadgeTech pHTemp2000 the channel’s corresponding function key or by using the UP and DOWN keys. 5.5.i.b Display Configuration By selecting “MORE” (either by pressing the F4 key on the Adjust Visibility Screen or by pressing the OK button) in the Display section the Display Configuration screen can be viewed. Here LCD screen contrast values can be set as well as the size the channels are displayed on the Main Screen.
Data Logger Manual Display The pHTemp2000’s LCD screen has options to be either on continuously or turn off automatically after 5 minutes of inactivity. This option can be changed by first pressing the F1 key to highlight the display parameter configuration tab. Once the tab is highlighted the option can be changed by pressing the F1 key repeatedly or using the UP and DOWN keys to select either “On” or “Auto”. Backlight Like the display, the LCD screen’s backlight also has power saving options.
MadgeTech pHTemp2000 5.5.ii.c Power Status Selecting “MORE” by either pressing the F4 key or the OK key while viewing the Display Update Mode screen brings up the Power Status screen. On this screen the battery type is displayed and should be changed by the user based on whether a Lithium or Alkaline battery is used in the pHTemp2000. This can be changed by first pressing the F1 button to highlight the type parameter configuration tab.
Data Logger Manual It is important to keep your device properly calibrated to ensure accurate readings. 5.5.iii.d Device Version Pressing the F4 key while viewing the Maximum or Minimum Device Range screens will display the Device Version screen, containing information such as firmware revision number and communications baud rate. Values on this screen cannot be modified. 5.5.iii.e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device Version screens.
MadgeTech pHTemp2000 Section 6: pHTemp2000 Screen Descriptions 6.1 Main Screen: Displays last measured values. F1 = STATUS: goes to status screens F2 = STATS: shows statistics menu F3 = UNITS: goes to unit selection screen F4 = SETUP: shows device configuration menu CANCEL = no function OK = no function UP = scrolls channel readings (only available while using large text) DOWN = scrolls channel readings (only available while using large text) 6.
Data Logger Manual OK = returns to main screen UP = no function DOWN = no function 6.3 Status Screens (Memory Status): Displays information about the device’s memory capabilities including percent of memory available (memory left), number of readings taken so far (readings), max number of readings (max readings), and wrap.
MadgeTech pHTemp2000 F3 = TIME: displays date and time screen F4 = MORE: displays ID parameters screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.5 ID Parameters Displays information relating to device identity. F1 = ID: no function F3 = MORE: displays the first status screen F4 = EXIT: returns to main screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.
Data Logger Manual OK = returns to main screen UP = no function DOWN = no function 6.7 Temperature Channel Statistics: Displays temperature statistics (maximum recorded value, minimum recorded value, and average recorded value, must use small or medium sized font to view all on one screen) based on channel (RTD Temperature or pH Probe).
MadgeTech pHTemp2000 F3 = no function F4 = EXIT: returns to Statistics Menu Screen CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.9 Type Statistics: Displays statistics from pH statistics (maximum recorded value, minimum recorded value, or average value).
Data Logger Manual F3 = no function F4 = EXIT: returns to Statistics Menu CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.
MadgeTech pHTemp2000 CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.13 Adjust Visibility: Displays options for changing the viewing of both channels on the main screen (either shows a particular channel or hides it.
Data Logger Manual F1 = CNTRST: highlights the contrast parameter configuration tab F2 = SIZE: highlights and then changes options of the channel size parameter F3 = MORE: moves back to the Adjust Visibility screen F4 = EXIT: returns to Display Configuration Menu CANCEL = returns to Device Configuration Menu OK = moves back to the Adjust Visibility screen UP = when contrast parameter configuration tab is highlighted increases contrast value DOWN = when contrast parameter configuration tab is highlighted inc
MadgeTech pHTemp2000 6.16 Display Update Mode Screen: Displays information regarding display refresh mode and refresh interval. F1 = MODE: first highlights and then changes update mode (Auto: screen refreshes periodically or Reading: refreshes only after a reading is taken) F2 = TIME: first highlights and then changes refresh interval.
Data Logger Manual 6.18 Device Information Screens (Minimum Device Range): Displays values indicating minimum internal temperature and external probe data (for thermocouple selected) detectable by the pHTemp2000.
MadgeTech pHTemp2000 6.20 Device Information Screens (Device Version): Displays device version information. F1 = VERS: no function F2 = FIRM: shows Firmware Version screen F3 = MORE: shows Device Range (Minimum) screen F4 = EXIT: Returns to Device Configuration Menu CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.21 Device Information Screens (Firmware Version): Displays device firmware version information.
Data Logger Manual 6.22 Calibration Information Screens (Calibration Date): Displays date of last calibration and due date of next calibration. For all Device Information Screens: F1 = DATE: no function F2 = TEMP: shows RTD temperature calibration information F3 = pH: shows pH probe calibration information F4 = EXIT: returns to Device Configuration Menu CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
MadgeTech pHTemp2000 6.24 Calibration Information Screens (External Probe Calibration): Displays calibration information for external probe channel. F1 = DATE: shows calibration date information F2 = TEMP: shows RTD temperature calibration information F3 = pH: shows pH calibration information F4 = Exit CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
Data Logger Manual 6.26 Device Reset Screen (Power Interruption): Displayed as notification when power is interrupted during device operation.
MadgeTech pHTemp2000 Section 7: Computer Interface: Insert the IFC200 into an available USB port. Fully insert male connector of the IFC200 interface cable into the female receptacle of the data logger*. *WARNING: Install driver before connecting a device using a USB for the first time. See the Data Logger Software manual for further information.
Data Logger Manual Section 8: Wall Mounting Power Supply Cable Slot Page 33
MadgeTech pHTemp2000 Section 9: Maintenance BATTERY WARNING Most MadgeTech data loggers contain a lithium battery. Do not cut the battery open, incinerate, or recharge. Do not heat lithium batteries above the specified operating temperature.* Dispose of the battery in accordance with local regulations. *See the individual specification sheets at www.madgetech.com. The pHTemp2000 does not have any user-serviceable parts except the battery which should be replaced periodically.
Data Logger Manual Section 10: Terms and Conditions All products furnished by MadgeTech, Inc. (“Seller”) shall be in accordance with the following terms and conditions unless otherwise stated in writing: These Terms and Conditions (“Terms and Conditions”) govern (a) all sales quotations and sales of components, equipment, parts, and other products (“Product”) from, and (b) all service proposals and provisions of services by Seller to the buyer of the Products (“Buyer”).
MadgeTech pHTemp2000 IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT OR ACCURACY, ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT, WITH RESPECT TO ANY OF THE SELLER MANUFACTURED PRODUCTS, CONSUMABLES OR SOFTWARE, OR ANY OF THE SELLER PROVIDED SERVICES. Any drawings submitted with the Products are only to show the general style, arrangement, and approximate dimensions of the Products. B. Equipment, Consumables, Software and Services Manufactured or Provided by Others.
6 Warner Road, Warner, NH 03278 Phone 603.456.2011 l Fax 603.456.2012 www.madgetech.com l info@madgetech.