Configuration
We recommend to use an IP address range of 10.0.0.x for MADRIX and InstaLight2022. The
subnet mask should be 255.0.0.0
For the use of Insta products, we suggest to only use 1000Mbit network components. That
means 1000Mbit network cards in your computer, 1000Mbit switches and a DHCP server with
support of 10/100/1000Mbit if your setup looks like the configuration shown above.
For the administration of the Insta network driver, please enable the network driver first. Go to
the menu "Preferences" -> "Options" or the press the keys "Ctrl-Alt-O". Select the tab
"Devices (Network)".
Here you can enable and disable the ROBE/Insta network driver. Use the edit field "Time To
Detect Fixtures (s)" to define how long MADRIX searches the network for InstaLight2022
network devices (type in a value in seconds).
We recommend to utilize at least a value of 10 to allow for a sufficient search.
Higher values are recommended for larger installations.
Furthermore, the option "White Adjustment" is included for Insta Light panels. MADRIX
automatically performs this automatic calibration with the start-up. Connected panels will adjust
their white value to the maximum value possible in the installation to ensure a similar color
temperature. If the adjustment takes longer than 100 seconds, MADRIX will send data
nevertheless. Uncheck this option if you want to deactivate it.