User manual
MADRIX PLEXUS 578
© 2011 inoage GmbH
"Valid Thru"
defines together with "Valid From" a time interval in which the event will be
triggered. "Valid Thru" sets the end point.
"Cycle
Interval"
defines a time period for the "Type" "Cycle" in HH:MM:SS (Hours:Minutes:Seconds).
Extension Ports:
The tab "Extension Ports" allows you to configure the individual pins of the Extension Port.
First, please select one PLEXUS Configuration you wish to edit.
Resets all settings to their default value. This will discard any changes you have made.
Please edit the following columns according to your requirements.
(Perform a double-click to change their values. Use Enter to apply your changes. Use Escape to
cancel.)
"Type"
defines the character for each Port. On the one hand, "Ports 1 - 6" can be either
"Digital Input" or "Analog Input". Therefore, only input is allowed for Ports 1 to 6.
On the other hand, "Ports 7 - 10" are only digital ports, but can be switched from
"Digital Input" to "Digital Output" and vice versa.
"Invert"
defines if the status of the Port (1 = On, 0 = Off) will be reversed to 0 = On, 1 =
Off.
"Action"
defines the type of event that will be triggered when a Port is triggered. Applicable
values are: "No", "Scene", "Master", "Speed", "PlayPause", "Freeze".
"PlayPause" will start or stop the playback. "Freeze" will halt the output.
"Value"
defines the "Action" in more detail. Enter a number to specify a certain Scene.
Enter a value from 0 to 100 for "Master". Enter a value from 0 to 1000 for "Speed".