16
Pin Assignment Available Settings
1 Ground
2 Port 1 Digital Input, Digital Output, Analog Input
3 Port 3 Digital Input, Digital Output, Analog Input
4 Port 5 Digital Input, Digital Output, Analog Input
5 Port 7 Digital Input, Digital Output
6 Port 9 Digital Input, Digital Output
7 Power 5 V, 100 mA max. (shared with Pin 9)
8 Ground
9 Power 5 V, 100 mA max. (shared with Pin 7)
10 Port 2 Digital Input, Digital Output, Analog Input
11 Port 4 Digital Input, Digital Output, Analog Input
12 Port 6 Digital Input, Digital Output, Analog Input
13 Port 8 Digital Input, Digital Output
14 Port 10 Digital Input, Digital Output
15 Ground
Extension Port – Remote Control
MADRIX
®
PLEXUS features a
15-pin, serial connector with
individually addressable ports. The
extension port makes it possible to
connect external analog or digital
devices for remote control. In MADRIX
®
, please open the menu ‘Tools’ à
‘PLEXUS Configuration…’ à tab ‘Extension Ports’ to configure each port
individually for the corresponding PLEXUS Configuration.
1
Extension
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
Web Server – Remote Control
MADRIX
®
PLEXUS provides an integrated web server. Connect your PLEXUS and
the remote device accessing the PLEXUS to a network. Open a web browser and
type in the IP address of your PLEXUS. The IP address can be found and changed
in the PLEXUS menu ‘Network’ à ‘IP Address’. Once loaded, the page will show
an interactive illustration of your device for remote control.
Please note: Make sure to use one and the same network and check if the
settings of the operating system and the settings of the PLEXUS are correct.