Manual
TABLE 1
Inductance Percent Test SRF(MHz) Resistance Rated DC Current
L(μH) Tolerance Frequency Typ. RDC(Ω)Max.IDC1(A) IDC2(A)
1.0 M,N 100kHz/0.25V 100 8m 16 10.0 1R0
2.2 N 100kHz/0.25V 60 18m 14 8.5 2R2
3.3 N 100kHz/0.25V 50 20m 12 6.5 3R3
4.7 N 100kHz/0.25V 35 23m 9.5 4.5 4R7
10 M,N 100kHz/0.25V 22 33m 8.0 3.5 100
15 M,N 100kHz/0.25V 18 42m 7.0 3.0 150
22 M,N 100kHz/0.25V 11 54m 5.5 2.5 220
33 M,N 100kHz/0.25V 9 80m 4.0 2.0 330
47 M,N 100kHz/0.25V 8 0.10 3.8 1.6 470
68 M,N 100kHz/0.25V 7 0.17 3.0 1.2 680
100 K,M 100kHz/0.25V 5 0.22 2.5 1.2 101
150 K,M 100kHz/0.25V 4 0.34 2.0 0.9 151
220 K,M 100kHz/0.25V 3.5 0.44 1.6 0.7 221
330 K,M 100kHz/0.25V 2.5 0.70 1.2 0.6 331
470 K,M 100kHz/0.25V 2.0 0.95 1.0 0.3 471
680 K,M 100kHz/0.25V 2.0 1.20 1.0 0.2 681
1000 K,M 100kHz/0.25V 1.5 2.00 0.8 0.1 102
※ □ specify the inductance tolerance,K(±10%),M(±20%),N(±30%)
※ IDC1: Based on inductance change (△L/Lo:drop 10% Max.) @ambient temperature 25℃
IDC2: Based on temperature rise (△T: 40℃ TYP.)
Rated DC Current: The less value which is IDC1 or IDC2.
MSCDB-1311-SERIES Page-2/8
MSCDB-1311-330□
MSCDB-1311-150□
Marking
MAGLAYERS
PT/NO.
MSCDB-1311-220□
MSCDB-1311-1R0□
MSCDB-1311-4R7□
MSCDB-1311-100□
MSCDB-1311-2R2□
MSCDB-1311-3R3□
MSCDB-1311-471□
MSCDB-1311-102□
MSCDB-1311-470□
MSCDB-1311-680□
MSCDB-1311-101□
MSCDB-1311-331□
MSCDB-1311-151□
MSCDB-1311-221□
MSCDB-1311-681□
MAG.LAYERS