Instruction Manual
MECHANICAL
TEST ITEM SPECIFICATION
There shall be Temperature profile of reflow soldering
P.2/9 Product picture & dimensions is added
no damage or
(reflow soldering) problems.
The specimen shall be passed through the reflow oven with the
condition shown in the above profile for 1 time.
The specimen shall be stored at standard atmospheric conditions
for 1 hour, after which the measurement shall be made.
ELECTRICAL
TEST ITEM SPECIFICATION TEST DETAILS
Temperature
△L/L20℃≦±10%
The test shall be performed after the sample has stabilized in
characteristics
0~2000 ppm/℃
calculated based on the value applicable in a normal
temperature and narmal humidity shall be △L/L20℃≦±10%.
Page-4/8
MSI-200904CP-SERIES-□-□□
Sodering temperature (℃)
soldering
(Peak temperature 260±3℃ 10 sec
Slow cooling
(Stored at room
temperature)
30 sec Min
(230
+0
℃)
300
250
200
150
100
50
2 min
10
sec.
2 min. or more
Pre-heating
150 ~ 180℃
MAG.LAYERS