Certifications 2

Page 1 of 6 3 Jan 2013
PRODUCT SAFETY DATA SHEET
1. Name of Product and Manufacturer
Name of Product : Nickel Metal Hydride Rechargeable cell or battery pack
Name of Company : Intec Industries Company Ltd.
Address : Rom 2703, Well Tech Centre, 9 Pat Tat Street, Sam Po Kong, HK
Telephone number : (852) 2885 1100
For emergency : (852) 2885 1193
Effective date : January 3, 2013
2. Hazards identification
GHS Classification : Not applicable
Hazard : Electrolyte, Nickel and Hydride compound are non-flammable.
Risk of explosion by fire if batteries are disposed in fire or heated
above 100 degrees C.
Stacking or jumbling batteries may cause external short circuits,
heat generation, fire or explosion.
Toxicity : Vapor generated from burning batteries, may make eyes, skin and
throat imitate.
3. Compositions
IMPORTANT NOTE: The battery cell should not be opened or exposed to heat because exposure
to the following ingredients contained within could be harmful under some circumstances.
Chemical Name Percentage by Weight
Cobalt 2.0-6.5%
Cobalt metal [CAS no: 7440 48 4]
Cobalt oxide [CAS no: 1307 96 6]
Cobalt hydroxide [CAS no: 21041 93 0]
Lithium hydroxide [CAS no: 1310 65 2] 0-3%
Manganese metal [CAS no: 7439 96 5] <4%
Rare Earth Metal <14%
Lanthanum [CAS no: 7439 91 0]
Cerium [CAS no: 7440 45 1]
Neodymium [CAS no: 7440 00 8]
Praseodymium [CAS no: 7440 10 0]
Nickel 30-50%
Nickel powder [CAS no: 7440 02 0]
Nickel oxide [CAS no: 1313 99 1]
Nickel hydroxide [CAS no: 12054 48 7]
Potassium hydroxide [CAS no: 1310 58 3] <6%
Sodium hydroxide [CAS no: 1310-73-2] 0-5%
Remarks: Concentrations may vary under different condition of charging or discharging
Intec Industries Co., Ltd.
Room 2703, Well Tech Centre
9 Pat Tat Street, San Po Kong, Hong Kong
Tel: (852) 2885 1100 Fax: (852) 2947 0588
Intec

Summary of content (6 pages)