Installation manual

26 Reference & Installation Manual
Fire Panic: Panic keys [7] and [9] (see page 24) or the
appropriate button(s) on a remote control (see page 18)
have been pressed.
Recent Closing: Reports when an alarm is generated after
arming the system within the period defined by the Recent
Close Delay (see page 30).
Section [140]
Auto-zone Shutdown: A zone communicates more than the
programmed number of transmissions in a single armed
period (see page 15).
Duress: A Duress code is keyed in (see page 12).
Paramedical alarm
Zone Tamper Report Codes
Section [141] to [144]
A report code can be programmed for each of the 16 available
zones. Whenever a tamper or wire fault occurs on a zone, the
Magellan console can send the appropriate report code to the
monitoring station identifying which zone was tampered.
If Tamper Recognition (see page 23) is disabled, the
console will not report the occurrence of any tampers,
wire faults or tamper restores.
Zone Tamper Restore Report Codes
Sections [145] to [148]
A report code can be programmed for each of the 16 available
zones. Whenever a tampered zone is restored, the Magellan
console can send the appropriate report code to the monitoring
station identifying which zone has been restored.
If Tamper Recognition (see page 23) is disabled, the console
will not report the occurrence of any tampers, wire faults or
tamper restores.
System Trouble Report Codes
Section [149] to [151]
Whenever the system generates one of the instances listed
below, the console can send the appropriate report code to the
monitoring station identifying the type of system trouble.
Section [149]
Console Tamper: A tamper has been detected on the
console itself (see Console Tamper Supervision on page
32).
AC Failure: Magellan has detected a loss of AC power.
Transmission of this report code can be delayed (see Power
Failure Report Delay on page 30).
Battery Failure: The backup battery is disconnected or
battery voltage is ≤ (less than or equal to) a certain voltage.
Timer Loss: The console has detected a loss in time or clock
failure.
Section [150]
Fail To Communicate: The Magellan console has failed all
attempts to communicate with the monitoring station. The
report code will be transmitted upon the next successful
attempt.
Wireless Low Battery: The battery voltage of an Omnia
wireless transmitter (motion detector or contact switch) has
dropped below recommended limits.
Tx Supervision Loss: Check-in Supervision (see page 23)
has been enabled and a transmitter is no longer
communicating with the system.
System Trouble Restore Codes
Sections [152] to [154]
Whenever the system restores one of the troubles listed in
sections [149] and [150] (see System Trouble Report Codes on
page 26), the Magellan console can send the appropriate report
code to the monitoring station identifying the type of system
trouble restored. If Telephone Line Monitoring is enabled (see
page 29), use the first two digits to program a TLM Restore
report code that the console can transmit.
Special Reporting Codes
Sections [155] and [156]
Whenever the system generates one of the instances listed
below, the Magellan console can send the appropriate report
code to the monitoring station identifying the type of system
occurrence.
Section [155]
Cold Start: The console was completely shut down (no
battery, no AC) and then was restarted.
Test Report: A test report has been generated automatically
(see page 30).
WinLoad Logout: The console has ended communication
with WinLoad.
Section [156]
Installer logon: Installer has entered the programming
mode.
Installer Logout: Installer has exited the programming mode.
Closing Delinquency: The last time the system was armed is
greater than the programmed Closing Delinquency timer
(see page 22).
Console Telephone Numbers
Magellan can dial up to two different monitoring station
telephone numbers and one Pager telephone number. You can
enter any digit from 0 to 9 and any special keys or functions (see
Table 9 on page 26) up to a maximum of 32 digits. If the number
is less than 32 digits, press the left [
ACTION
] key (
OK
) to save the
message.
Table 9: Special Keys for Telephone Numbers
Keys to press Action or Value
[*] *
[#] #
Center [
ACTION
] (pause) key
Add a 4-second pause to the
telephone number. Press the key and
a “P” will be inserted into the
telephone number