Installation manual

10 Programming Guide
System Timers
Section Data (value from 000 to 255) Description Defaults
[060]
____/____/____ seconds
Entry delay 1 (
)
045 secs.
[061]
____/____/____ seconds
Entry delay 2 (
)
045 secs.
[062]
____/____/____ seconds
Exit delay (
)
060 secs.
[063]
____/____/____ minutes
Bell cut-off time (
)
004 mins.
[064] ____/____/____ x 15 minutes No movement time Disabled
[065] ____/____/____ seconds (minimum 10 seconds) Intellizone delay 045 secs.
[066] ____/____/____ seconds Recent closing delay Disabled
[067] ____/____/____ times Auto-zone shutdown 005 times
[068] ____/____/____ seconds PGM1 timer 005 secs.
[069] ____/____/____ seconds PGM2 timer 005 secs.
[070] ____/____/____ minutes Power failure report delay 015 mins.
[071] ____/____/____ days Auto-test report Disabled
[072] ____/____/____ rings Number of rings 008 rings
[073] ____/____/____ seconds TLM fail timer 032 secs.
[074] ____/____/____ seconds Answering machine override delay 030 secs.
[075] ____/____/____ seconds Delay alarm transmission Disabled
[076] ____/____/____ seconds (maximum 130 seconds) Delay between dialing attempts 020 secs.
[077] ____/____/____ seconds Pager/voice delay 005 secs.
[078] ____/____/____ seconds Remote panic disarm lock delay 020 secs.
[079] ____/____/____ repetitions Voice reporting message repetitions 003 reps.
J[4] J[4]
J[4] J[4]
J[4] J[4]