Specifications

Magellan 13
Appendix 1: PGM Event Table
Event Group # Sub-group #
00 = Zone closed
01 to 16 = Zone number
99 = Any zone number
01 = Zone opened
02 = System status 00 = N/A
01 = N/A
02 = Silent alarm
03 = Buzzer alarm
04 = Steady alarm
05 = Pulsed alarm
06 = Strobe
07 = Alarm stopped
08 = Squawk ON
09 = Squawk OFF
10 = Ground start
11 = System disarmed
12 = System armed
13 = Entry delay engaged
99 = Any system status event
03 = Bell status 00 = Bell OFF
01 = Bell ON
02 = Bell Squawk Arm
03 = Bell Squawk Disarm
04 = Future use Future use
05 = Non-reportable event 00 = Telephone line trouble
01 = Future use
02 = Arm with no entry delay
03 = Arm in Stay mode
04 = Arm in Force mode
05 = Full arm when armed in Stay mode
06 = PC fail to communicate
07 = Future use
08 = Future use
09 = Doorbell 1 battery trouble
10 = Doorbell 1 battery trouble restore
11 = Doorbell 2 battery trouble
12 = Doorbell 2 battery trouble restore
13 = Utility Key 1 pressed (keys [1] and [9] from the center keypad)
14 = Utility Key 2 pressed (keys [2] and [10] from the center keypad)
15 = Utility Key 3 pressed (keys [3] and [11] from the center keypad)
16 = Utility Key 4 pressed (keys [4] and [12] from the center keypad)
17 = Utility Key 5 pressed (keys [5] and [13] from the center keypad)
18 = Utility Key 6 pressed (keys [6] and [14] from the center keypad)
19 = Utility Key 7 pressed (keys [7] and [15] from the center keypad)
20 = Utility Key 8 pressed (keys [8] and [16] from the center keypad)
21 = User remote access granted (MG-6060 only)
22 = User remote access denied (MG-6060 only)
23 = Tamper generated alarm
24 = Supervision loss generated alarm
99 = Any non-reportable event
06 = Remote access
01 to 16 = User number
99 = Any user number
07 = PGM activation (Remote control button option “B”; see page 10)
08 = PGM activation (Remote control button option “C”; see page 10)
09 = Cold Start zone 01 to 16 = Zone number
99 = Any zone number
10 = Future use Future use
11 = Smoke Maintenance signal 01 to 16 = Zone number
99 = Any zone number
12 = Delay zone alarm transmission 01 to 16 = Zone number
99 = Any zone number
13 = Arming with user 01 to 16 = User number
99 = Any user number