User guide

Installation
MultiView™ II AK600DP/AK1200DP Installation and User Guide 10
4.4.2 Skew Compensation Settings
If the AkuComp-II skew module is installed, it is possible to quickly adjust the RGB values when the MVII-
AK600(1200)DP is operating in normal mode. The EQ/SKEW indicators 1-8 will change accordingly to show (in
“bargraph” form) 0 to 100% of the available SKEW adjustment range (0 to 65nSec).
For best results, use the Magenta EQ/Skew test pattern image if possible. A test pattern
image and video instructions is available at http://www.magenta-research.com/test.
If skew compensation is required, but the skew module is not installed, call for technical
assistance. Your product may need to have the skew-module added to it.
The following figure shows the test image you can use to make the SKEW adjustment.
Figure 6: Image Adjustment Utility Skew
To adjust skew:
1. From normal mode, press and hold the SKEW/SEL button until the SKEW/RGB indicator turns on
RED. Release the SKEW button.
2. Press the UP or DOWN button repeatedly to adjust the RED skew value.
3. Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn GREEN.
4. Press the UP or DOWN button repeatedly to adjust the GREEN value.
5. Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn BLUE.
6. Press the UP or DOWN button to adjust the BLUE value.
7. Pressing the SKEW/SEL button again will return you to step-2, allowing adjustment of the RED skew
again.
8. To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the CFG button.