User guide

Installation
MultiView™ II AK600DP/AK1200DP Installation and User Guide 16
4.5.7 4
th
Pair Termination Settings (CFG2: LED3)
The AK600 provides settings for 4
th
pair termination: ON or OFF. This setting has an effect only for “-S”, “-A”
and S/PDIF operating modes.
Note: It is not possible to access the 4
th
-pair setting if an option board is installed since this setting is ignored.
Set to ON for all single-receiver applications, and for the last receiver in a daisy-chained
configuration. This is the factory-default.
Set to OFF only for mid-span receivers in a daisy-chain configuration.
Perform the following procedure while the receiver is in the normal operating state (CFG indicator is off):
1. Press and hold the CFG button until the CFG indictor is ON.
a. LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright/on.
2. Press and release the SKEW/SEL button five times.
a. The CFG indicator will start flashing.
b. LEDs 1-8 will show the current value for all Mode-2 configuration settings as bright/off.
3. Press and release the SKEW/SEL button twice.
4. LED indicator 3 should be illuminated (either DIM or ON); all others (indicators 1, 2 and 4-8) should be
off.
5. Use the UP and DOWN buttons to turn 4
th
-pair termination ON (bright) or OFF (dim).
6. To leave configuration-mode-2, leave the buttons untouched for 10 seconds or press the CFG button.