User manual

Magma
Roben 3 | Chapter 3 Verify Installation
91
In Windowsà Control Panel à Device Manager à View by connection
You should see these three PCI-to-PCI bridges. Right click on it and select Properties, select Hardware Ids from
dropdown list, you should see PCI\Ven_111D
Q: My host computer is having problem linking up with the expansion chassis. I have both interface
cards installed and seated firmly in their corresponding slot; one is installed in the host computer PCIe
slot and the other one in the expansion PCIE slot. Is there something wrong with the Interface card?
A: When using the 01-04973-03, in which comes in pair, one should be set to OFF-host and the other is set to ON-
Exp.
1. There's a Red Dip switch on the interface card that must be set correctly in order to work. The Red Dip
switch is labeled SW1.
2. 01-04973-03, SW1 when set to ON=EXP should be installed only inside the Magma Expansion unit.
3. 01-04973-03, SW1 when set to OFF=HOST should be installed inside the host computer.
4. If the 01-04973-03 cards are not set properly your computer won't link up with the Magma expansion.
See photos below: