Computer Hardware User Manual

Quattro DC Interconnections
16
GND
L(1
)
L(2
)
L(3
)
* Note 1
* Note 1
H(X) H(1)
Provided for
the Primary
side of the
230V control
power
transformer
To Quattro Drive
F1
F2
Internal Control
Power
2
3
TB1
Motor Field Control
SWout (+)
DCout (-)
A
24
Motor Shunt Field
(F1)(F2
)
* Note 1
* Note 1
4
3
2 1
TB1K1 K1 TB1 M
E
TB1 TB1
Located on A9
Safety Chain
* Note 1
Safety Chain
DBR
1-4
DBR
5-8
M
E
M
E
M
E
(4) (3)
(5) (6)
(2) (1)
(A1)
(A2)
* Note 1
Encoder to
A
6TB1
Notes:
1. * indicates components
not supplied by Magnetek
Hoist Moto
r
K1
Part of A9
M
E
M
E
M
E
(21) (22) (13) (14) (43) (44)
Motor Contactor Auxiliaries
230VAC hi 230VAC lo
Control Power
Figure 2: Quattro DC Power Connections