User Manual

TROUBLESHOOTING FOR ALL TRIODE MODELS
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
No sound, meter lights
are on
Interconnect not properly
installed
Preamp set to incorrect
source
Preamp set to tape monitor
source, if preamp has such
a function
Power amplifier is off
Tube failure
Verify installation of
interconnects
Turn preamp to input
where tuner is connected
On preamp defeat tape
monitor function
Turn amplifier on
Replace with 6922 tube
*With MD-102t, MD-106t replace
with Amperex bugle Boy 6922
tube (or equivalent)
TRIODE TUBE SPECIFICATIONS
Filament current (max) 330 mA (min) 270 mA
Anode current (1) (max) 1.07 mA (min) 0.92 mA
Anode current (2) (max) 1.07 mA (min) 0.92 mA
Total harmonic distortion < 1.8%
MD 106T and MD 102T, test sheets are included in the tube box
For models MD-102t, MD-106t the tubes are matched, and certified Amperex Bugle
Boy Tubes.

Summary of content (1 pages)